P546
[-01]
Function bus-setpoint
...
(bus setpoint function)
[-03]
0 ... 36
In this parameter, a function is allocated to the output setpoint during bus actuation.
{ [-01] = 1 }
NOTE:
{ [-02] = 0 }
{ [-03] = 0 }
[-01] = Bus-setpoint 1
Possible values which can be set:
10 = PI supervised current freq.
11 = Torque current limit, "Torque
12 = Torque current limit off,
Pos : 544 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Param eter P546 – Funk tion Bus- Sollw erte_Ergänz ung [SK 2xx E, SK 2xx E-FDS] @ 19\m od_1506006002157_14638.docx @ 2366072 @ @ 1
Pos : 545 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Param eter P549 – Funk tion Poti- Box [SK 1x 0E, SK 2x xE, SK 2xx E-FDS] @ 2\mod_1346932172758_14638.docx @ 43364 @ @ 1
Potentiometer Box function
P549
(Potentiometer Box function)
0 ... 16
This parameter provides the possibility of adding a correction value (fixed frequency, analog, bus)
to the current setpoint value by means of the Simple Box/Parameter Box keyboard.
{ 0 }
The adjustment range is determined by the auxiliary setpoint value P410/411.
Pos : 546 /Allgem ein/Allgem eingültig e Module/---------Seitenumbr uc h k ompakt --------- @ 13\m od_1476369695906_0.doc x @ 2265496 @ @ 1
BU 0200 en-US-4920
For further details, please refer to the relevant bus manual or the description for
(P400). (Values from 0% ... 100% correspond to 0000
For standardization of the setpoint values: (please see chapter 8.9 "Standardization
of setpoint/target values").
0 = Off
1 = Setpoint frequency (16 bit)
2 = Frequency addition
3 = Frequency subtraction
4 = Minimum frequency
5 = Maximum frequency
6 = Current value process control
7 = Nom. Val. Process ctrl.
8 = Pl current frequency
9 = PI ltd. Current freq.
current limited"
"Torque current switch-off limit"
0 = Off
1 = Setpoint frequency, with(P509)≠ 1
control via USS is possible
[-02] = Bus-setpoint 2
13 = Current limit, "Current limited"
14 = Current limit off
"Current switch-off limit"
15 = Ramp time, (P102/103)
16 = Pre-tension Torque, ((P214) multiplication)
17 = Multiplication
18 = Curve control
19 = Servo-mode Torque
20 = BusIO InBits 0-7
21 = ...25 reserved, POSICON
31 = Digital output IOE, sets the state of DOUT of
the first IOE
32 = Analog output IOE, sets the value AOUT of the
first IOE), condition: P418 = Function "31"
Value must be between 0 and 100 (0hex and
64hex). Otherwise the minimum value is
output at the analog output.
33 = Nom. Val. torque process ctrl., "Setpoint
torque process controller"
34 = d-corr. F process
35 = d-corr. Torque
36 = d-corr. F+Torque
2 = Frequency addition
3 = Frequency subtraction
5 Parameter
S
P
... 4000
hex
[-03] = Bus-setpoint 3
S
203
,)