7.2.2 Electrical data 1~230 V

Device model
Rated motor power
(4-pole standard motor)
Line voltage
Input current
Output voltage
3), 4)
Output current
FLA
Min. braking resistance
Motor mounting (ventilated)
Max. continuous power/max. continuous current
Max. permissible ambient temp. with nominal output current
S1
S3 70% ED 10 min
S6 70% ED 10 min (100%/20% Mn)
Wall mounting (ventilated/unventilated)
Max. continuous power/max. continuous current
Max. permissible ambient temp. with nominal output current
S1
S3 70% ED 10 min
S6 70% ED 10 min (100%/20% Mn)
Class
CC, J, R, T, G, L
Bussmann FRS-
(≥ 230 V)
1) Pay attention to derating curve ( section 8.4.4 "Reduced output current due to line voltage").
2) FLA – Full-load current, maximum current for the entire line voltage range as stated above (200 V – 240 V) according to UL/CSA
3) FLA (S1-40°C), FLA motor mounting: relates to a motor with fans
4) SK 21xE and SK 23xE devices: For use of safe functions (functional safety: STO and SS1) the restrictions regarding the permissible temperature
range according to
BU 0230
must be noted.
5) Maximum permissible short-circuit current in the grid
6) The use of an SK TU4-MSW(-...) module, limits the permissible short circuit in the grid to 10 kA
7) "inverse time trip type" in acc. with UL 489
a) Size 2: only SK 2x5E
a) 5.4 A when using a suitable fan
Pos : 726 /Allgem ein/Allgem eingültig e Module/---------Seitenumbr uc h k ompakt --------- @ 13\m od_1476369695906_0.doc x @ 2265496 @ @ 1
BU 0200 en-US-4920
SK 2xxE...
-250-123-
Size
1
230 V
0.25 kW
1
240 V
/
hp
3
230 V
1)
rms
3.9 A
2)
FLA
3.9 A
230 V
1)
rms
1.7 A
2)
1.7 A
motor mounting
2)
FLA
1.7 A
wall mounting
75 Ω
Accessories
4)
S1-50°C
0.25kW/1.6A
S1-40°C
0.25kW/1.7A
S1-30°C
0.25kW/1.7A
49°C
50°C
50°C
4)
S1-50°C
0.25kW/1.5A
S1-40°C
0.25kW/1.7A
S1-30°C
0.25kW/1.7A
44°C
50°C
45°C
slow-blowing
10 A
5)
Isc
[A]
RK5
x
10 A
(x)
x
10 A
(x)
x
R-10
(x)
x
10 A
-370-123-
-550-123-
1
1
0.37 kW
0.55 kW
½ hp
¾ hp
1 AC 200 ... 240 V, ± 10%, 47 ... 63 Hz
5.8 A
7.3 A
5.8 A
7.3 A
3 AC 0 ... line voltage
2.2 A
3.0 A
2.2 A
2.6 A
2.2 A
2.9 A
75 Ω
75 Ω
0.25kW/1.8A
0.37kW/2.5A
0.37kW/2.0A
0.55kW/2.8A
0.37kW/2.2A
0.55kW/2.9A
33°C
36°C
45°C
45°C
40°C
40°C
0.37kW/2.2A
0.37kW/2.7A
0.37kW/2.2A
0.55kW/2.9A
0.37kW/2.2A
0.55kW/2.9A
50°C
42°C
50°C
45°C
50°C
45°C
General fuses (AC) (recommended)
10 A
16 A
UL-approved fuses (AC)
10 A
10 A
10 A
10 A
R-10
R-10
10 A
10 A
7 Technical Data
-750-123-
-111-123-
a)
a)
2
2
0.75 kW
1.10 kW
1 hp
1½ hp
10.2 A
14.7 A
14.6 A
10.1 A
4.0 A
5.5 A
3.9 A
5.4 A
b)
3.9 A
4.4 A
75 Ω
75 Ω
0.55kW/3.4A
0.75kW/4.3A
0.55kW/3.7A
0.75kW/4.8A
0.75kW/4.0A
1.10kW/5.4A
35°C
29°C
45°C
40°C
40°C
35°C
0.75kW/4.0A
0.75kW/4.3A
0.75kW/4.0A
0.75kW/4.8A
0.75kW/4.0A
1.10kW/5.3A
50°C
27°C
50°C
40°C
50°C
35°C
16 A
16 A
30 A
30 A
30 A
30 A
R-30
R-30
25 A
25 A
239