nord NORDAC FLEX SK 200E Series User Manual page 219

Table of Contents

Advertisement

Pos : 635 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Param eter P755 – Statistik Systemfehler @ 0\mod_1328178677434_14638.docx @ 15162 @ @ 1
Stat. System error
P755
(system faults statistics)
0 ... 9999
Number of system faults during the operating period P714.
Pos : 636 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Param eter P756 – Statistik Tim e Out @ 0\m od_1328178715996_14638.docx @ 15163 @ @ 1
Stat. Timeout
P756
(Timeout statistics)
0 ... 9999
Number of Time out errors during the operating period P714.
Pos : 637 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Param eter P757 – Statistik Kundenfehler @ 0\mod_1328178758542_14638.doc x @ 15164 @ @ 1
Stat. Customer error
P757
(Customer error statistics)
0 ... 9999
Number of Customer Watchdog faults during the operating period P714.
Pos : 638 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Param eter P760 – Ak tueller Str om [SK 1x0E, SK 2xxE, SK 2xx-FD S] @ 2\m od_1346932211538_14638.docx @ 43748 @ @ 1
Input current
P760
(present line current)
0.0 ... 999.9 A
Displays the actual input current.
Pos : 639 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Param eter P780 – Geräte ID [SK 2xxE(-FD S)] @ 50\m od_1600932300383_14638.docx @ 2672647 @ @ 1
P780
[-01]
Device ID
...
(Device ID)
[-14]
Display of the serial number (14-digit) of the device.
0 ... 9 and A...Z
(char)
{ 0 }
Pos : 640 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P700- P799/Param eter P799 – Betriebss tunden l etz te Störung 1...5 @ 0\m od_1328178802042_14638.docx @ 15165 @ @ 1
P799
[-01]
Op.-time last error
...
(Operating time, last fault 1...5)
[-05]
0.1 ... ___ h
This parameter shows the operating hours counter status (P714) at the moment of the last fault.
Array 01...05 corresponds to the last fault 1...5.
Pos : 642 /Anleitungen/El ektr onik /FU und Starter/6. M eldung en zum Betriebsz ustand/_M eldungen z um Betri ebszus tand_01 (Übersc hrift + Inhalt) [SK xxx E] @ 3\m od_1361795506047_14638.docx @ 59690 @ 1555 @ 1
BU 0200 en-US-4920
– Display via NORDCON: as a coherent serial number of the device.
– Display via Bus: ASCII code (decimal). Each array must be read out separately.
5 Parameter
S
S
S
S
219