NORDAC SK 200E Manual

5.3 Motor data / characteristic curve parameters

Parameter
[factory setting]
P200
0 ... 45
[ 0 ]
P201
10.0 ... 400.0 Hz

[
]
P202
150 ... 24000 rpm
[***]
P203
0.1 ... 300.0 A
[***]
*** These settings are dependent on the nominal power of the FI or the selection in parameter P200.
98
Setting value / Description / Note
Motor list
The factory settings for the motor data can be edited with this parameter. The factory setting in
parameters P201...P209 is a 4-pole DS standard motor with the nominal FI power setting.
By selecting one of the possible digits and pressing the OK key, all motor parameters
(P201...P209) are adjusted to the selected standard power. The basis for the motor data is a 4-
pole DS standard motor
0 = No change to data
1 = No motor: In this setting, the FI operates without current control, slip compensation and
pre-magnetising time, and is therefore not recommended for motor applications. Possible
applications are induction furnaces or other applications with coils and transformers. The
following motor data is set here:
50.0Hz / 1500rpm / 15.0A / 400V / 0.00kW / cos  =0.90 / Star / R
2 = 0.25kW 230V
14 = 0.75kW 230V
3 = 0.33Hp 230V
15 = 1.0PS 230V
4 = 0.25kW 400V
16 = 0.75kW 400V
5 = 0.33Hp 460V
17 = 1.0PS 460V
6 = 0.37kW 230V
18 = 1.1kW 230V
7 = 0.50HP = 230V
19 = 1.5PS 230V
8 = 0.37kW 400V
20 = 1.1kW 400V
9 = 0.50HP = 460V
21 = 1.5PS 460V
10 = 0.55kW 230V
22 = 1.5kW 230V
11 = 0.75Hp 230V
23 = 2.0PS 230V
12 = 0.55kW 400V
24 = 1.5kW 400V
13 = 0.75Hp 460V
25 = 2.0PS 460V
As P200 returns to = 0 after the input confirmation, the control of the set motor can
NOTE:
be implemented via parameter P205.
If DIP switch 7 (50/60Hz operation, Section 4.1.1) is switched over, the appropriate
nominal motor data according to the FI power rating are reloaded from the P200 list.
Nominal frequency
The motor nominal frequency determines the V/f break point at which the FI supplies the
nominal voltage (P204) at the output.
Nominal speed
The nominal motor speed is important for the correct calculation and control of the motor slip
and the speed display (P001 = 1).
Nominal current
The nominal motor current is a decisive parameter for the current vector control.
Subject to technical alterations
Device
Supervisor
0,01  / I
S
26 = 2.2kW 230V
38 = 5.5kW 400V
27 = 3.0PS 230V
39 = 7.5PS 460V
28 = 2.2kW 400V
40 = 7.5kW 230V
29 = 3.0PS 460V
41 = 10PS 230V
30 = 3.0kW 230V
42 = 7.5kW 400V
31 = 3.0kW 400V
43 = 10PS 460V
32 = 4.0kW 230V
44 = 11kW 400V
33 = 5.0PS 230V
45 = 15PS 460V
34 = 4.0kW 400V
35 = 5.0PS 460V
36 = 5.5kW 230V
37 = 7.5PS 230V
S
S
S
Parameter
set
P
6.5A
EMPTY
P
P
P
BU 0200 GB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents