Pos : 302 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P000- P099/Param eter P002 – Displ ay-F aktor @ 0\m od_1327573818457_14638.docx @ 14893 @ @ 1
Display factor
P002
(display factor)
0.01 ... 999.99
The operating value selected in parameter P001 >Selection of operating value display< is multiplied
with the scaling factor and displayed in P000 >Status display<.
{ 1.00 }
It is therefore possible to display system-specific operating values such as the flow rate.
Pos : 303 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P000- P099/Param eter P003 – Supervis or-Code [SK 1x 0E, SK 2xx E, SK 2xxE-FD S] @ 2\m od_1346931544673_14638.docx @ 42131 @ @ 1
P003
Supervisor code
(supervisor code)
0 = The supervisor parameters and groups P3xx/P6xx are not visible, otherwise all.
0 ... 9999
{ 1 }
1 = All parameters are visible, except groups P3xx and P6xx.
2 = All parameters are visible, except group P6xx.
3 = All parameters are visible.
4 = ... 9999, only parameters P001 and P003 are visible.
If parameterization is carried out with the NORDCON software, settings 4 ... 9999 behave like
setting 0. Settings 1 and 2 behave like setting 3.
Pos : 304 /Allgem ein/Allgem eingültig e Module/---------Seitenumbr uc h k ompakt --------- @ 13\m od_1476369695906_0.doc x @ 2265496 @ @ 1
140
Stator R ID
Rotor R ID
Stator stray L ID
Stator L ID
Information
Stator resistance determined by means of measurement (P220)
Rotor resistance determined by measurement ((P220) function 2)
Leakage inductance determined by measurement ((P220) function
2)
Inductance determined by measurement ((P220) function 2)
Reserved
Display via NORDCON
S
BU 0200 en-US-4920