Source Control Word
P509
(Control word source)
0 ... 4
Selection of the interface through which the VFD is controlled.
{ 0 }
0 =
1 =
2 =
3 =
4 =
NOTE: For details of the optional bus systems, please refer to the relevant supplementary bus manuals.
Pos : 494 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Param eter P509 – Quell e Steuerwort - Ergänz ung [SK 2xx E] @ 9\m od_1448293499605_14638.docx @ 266001 @ @ 1
As an alternative to setting the parameter, systembus can also be selected with DIP switch S1:3.
Pos : 495 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Param eter P510 – Quell e Sollw erte [SK 1x 0E, SK 2xx E] @ 2\m od_1346932165333_14638.docx @ 43076 @ @ 1
P510
Source Setpoints
[-01]
(setpoints source)
[-02]
0 ... 4
Selection of the setpoint source to be parameterized:
{ [-01] = 0 }
[-01] = Source main setpoint
{ [-02] = 0 }
Selection of the interface via which the VFD receives the setpoint.
Pos : 496 /Anleitungen/El ektr onik /FU und Starter/5. Par ameter/Par ameter auflistung (P000 ...)/P500- P599/Param eter P511 – USS-Baudrate [SK 1x 0E, SK 2x xE, SK 2xx-FD S] @ 2\mod_1346932165972_14638.docx @ 43100 @ @ 1
USS baud rate
P511
(USS baud rate)
0 ... 3
Setting of the transfer rate (transfer speed) via the RS485 interface. All bus participants must
have the same baud rate setting.
{ 3 }
0 =
1 =
Pos : 497 /Allgem ein/Allgem eingültig e Module/---------Seitenumbr uc h k ompakt --------- @ 13\m od_1476369695906_0.doc x @ 2265496 @ @ 1
BU 0200 en-US-4920
Contr.term. or keyb., "Control terminals or keyboard control" ** with the Simple Box (if
P510=0), the Parameter Box or via BUS I/O Bits.
Contr. Terminal only *, the VFD can only be controlled via the digital and analog inputs or
via the bus I/O Bits.
USS*, the control signals (enable, rotation direction, etc.) are transferred via the RS485
interface, and the setpoint is transferred via the analog input or the fixed frequencies.
Systembus *, setting for control by master via a bus interface
Systembus broadcast *, setting for actuation by a master drive in Master/Slave mode
(e.g. with synchronous applications)
*)
Keyboard control (Simple Box, Parameter Box) is disabled, parameterization is still
possible.
**) If communication is interrupted during keyboard control (timeout 0.5 s),
the VFD will block without an error message.
0 = Auto: The source of the setpoint is
automatically derived from the setting of
parameter P509.
1 = Control terminal only, digital and
analog inputs control the frequency,
including fixed frequencies
4800 baud
9600 baud
-
www.nord.com
-
[-02] = Source 2nd setpoint
2 = USS, see P509
3 = Systembus, see P509
4 = Systembus broadcast, see P509
2 =
19200 baud
3 =
38400 baud
5 Parameter
S
S
S
191