BU 0200 en-US-4920
"Suitable For Use On A Circuit Capable Of Delivering Not More Than 65 000 rms Symmetrical
Amperes, ____ Volt maximum",
"When Protected by Circuit Breaker (inverse time trip type) in accordance with UL 489, rated
______ Amperes, and _______Volts", as listed in
"Suitable For Use On A Circuit Capable Of Delivering Not More Than 100 000 rms Symmetrical
Amperes, ____ Volts Maximum" and minimum one of the two following alternatives.
When used together with Accessory SK TU4-MSW:
"Suitable For Use On A Circuit Capable Of Delivering Not More Than 10 000 rms Symmetrical
Amperes, ____ Volts Maximum" and minimum one of the two following alternatives.
1. "When Protected by Fuses manufactured by Bussmann, type ______", as listed in
2. "When Protected by class RK5 Fuses or faster or when Protected by High-Interrupting
Capacity, Current Limiting Class CC, G, J, L, R, T, etc. Fuses, rated ______ Amperes, and
1)
_____ Volts", as listed in
.
"Suitable for motor group installation on a circuit capable of delivering not more than 100 000
rms symmetrical amperes, 500 V max" "When Protected by class RK5 Fuses or faster, rated
30_Amperes"
"Suitable for motor group installation on a circuit capable of delivering not more than 100 000
rms symmetrical amperes, 500 V max" "When Protected by High-Interrupting Capacity, Current
Limiting Class CC, G, J, L, R, T, etc. Fuses rated 30 Amperes"
"Suitable for motor group installation on a circuit capable of delivering not more than 10 000
rms symmetrical amperes, 500 V max" "When Protected by Circuit Breaker (inverse time trip
type) in accordance with UL 489, rated 30 Amperes and 500 Volts min"
If device is used for Canadian market and bears the cUL Listing mark: "For Canada SCCR is
limited to 5 000 rms Symmetrical Amperes.".
Marking not required for UL only marked devices.
"Suitable For Use On A Circuit Capable Of Delivering Not More Than 100 000 rms Symmetrical
Amperes, 240 Volts Maximum When Protected By High-Interrupting Capacity, Current Limiting
Type Fuses such as Class CC, G, J, L, R, T, etc., rated 300V/60A."
"Suitable For Use On A Circuit Capable Of Delivering Not More Than 10 000 rms Symmetrical
Amperes, 240 Volts Maximum When Protected By A Circuit Breaker Having An Interrupting
Rating Not Less Than 10 000 rms Symmetrical Amperes, 300 Volts Maximum."
"Suitable For Use On A Circuit Capable Of Delivering Not More Than 100 000 rms Symmetrical
Amperes, 500 Volts Maximum When Protected By High-Interrupting Capacity, Current Limiting
Type Fuses such as Class CC, G, J, L, R, T, etc., rated 600A/60A."
"Suitable For Use On A Circuit Capable Of Delivering Not More Than 10 000 rms Symmetrical
Amperes, 500 Volts Maximum When Protected By A Circuit Breaker Having An Interrupting
Rating Not Less Than 10 000 rms Symmetrical Amperes, 600 Volts Maximum."