Potentiometers P1 And P2 (Sk 2X0E Size 4 And Sk 2X5E) - nord NORDAC FLEX SK 200E Series User Manual

Table of Contents

Advertisement

NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
Pos : 244 /Anleitungen/El ektr onik /FU und Starter/4. Inbetriebnahm e/SK 1x xE, SK 2xx E, -FD S/Inbetriebnahme Gerät/Potentiom etern P1 und P2 (SK 2x0E BG 4 und SK 2x 5E) [SK 2xxE] @ 1\mod_1343222441209_14638.docx @ 37550 @ 4 @ 1
4.3.2.4

Potentiometers P1 and P2 (SK 2x0E size 4 and SK 2x5E)

The setpoint can be set to a fixed value with integrated potentiometer P1. Adjustment of startup and
braking ramps can be made via potentiometer P2.
P1
(continuous)
0%
P102/103
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
The function of P1 and P2 depends on DIP 4/5. The meaning changes according to the setting.
By default, P1 sets the setpoint value of 0%-100% and P2 sets the ramp from 0.2-7 s.
Pos : 245 /Allgem ein/Allgem eingültig e Module/---------Seitenumbr uc h k ompakt --------- @ 13\m od_1476369695906_0.doc x @ 2265496 @ @ 1
110
Potentiometers
P105
0.2 s
10 Hz
0.3 s
20 Hz
0.5 s
30 Hz
0.7 s
40 Hz
1.0 s
50 Hz
2.0 s
60 Hz
3.0 s
70 Hz
5.0 s
80 Hz
7.0 s
90 Hz
10.0 s
100 Hz
Potentiometers
P2
P1
P2
(stepped)
-
-
1
P102/103
2
0.2 s
3
0.3 s
4
0.5 s
5
0.7 s
6
1.0 s
7
2.0 s
8
3.0 s
9
5.0 s
10
7.0 s
-
P104
2 Hz
5 Hz
10 Hz
15 Hz
20 Hz
25 Hz
30 Hz
35 Hz
40 Hz
BU 0200 en-US-4920

Advertisement

Table of Contents
loading

Table of Contents