NORDAC FLEX (SK 200E ... SK 235E) – Users Manual for Frequency Inverters
Device model
Rated motor power
(4-pole standard motor)
Line voltage
Input current
Output voltage
FLA
3), 4)
Output current
Min. brake resistance
Motor mounting (ventilated), or wall mounting with SK TIE4-WMK-L-1 (or -2) (ventilated)
Max. continuous power/max. continuous current:
Max. permissible ambient temp. with rated output current
S1
S3 70% ED 10 min
S6 70% ED 10 min (100%/20% Mn)
Wall mounting (unventilated)
Max. continuous power/max. continuous current:
Max. permissible ambient temp. with nominal output current
S1
S3 70% ED 10 min
S6 70% ED 10 min (100%/20% Mn)
Class
CC, J, R, T, G, L
Bussmann FRS-
(≥ 230 / 400 V)
1) Pay attention to derating curve ( section 8.4.4 "Reduced output current due to line voltage").
2) FLA – Full-load current, maximum current for the entire line voltage range as stated above (380 V – 500 V) according to UL/CSA
3) FLA (S1-45°C), FLA motor mounting: relates to a motor with fans
4) SK 21xE and SK 23xE devices: For use of safe functions (functional safety: STO and SS1) the restrictions regarding the permissible temperature
range according to
BU 0230
must be noted.
5) Maximum permissible short-circuit current in the grid
6) The use of an SK TU4-MSW(-...) module, limits the permissible short circuit in the grid to 10 kA
7) "inverse time trip type" in acc. with UL 489
a) 6.7 A when using a suitable fan
a) 8.5 A when using a suitable fan
a) 11.0 A when using a suitable fan
a) 14.0 A when using a suitable fan
244
SK 2xxE...
-301-340-
Size
2
400 V
3.0 kW
480 V
4 hp
400 V
1)
rms
7.0 A
2)
FLA
6.3 A
400 = 0 – 10 V
1)
rms
7.5 A
2)
6.7 A
motor mounting
a)
5.5
2)
FLA
wall mounting
(S1-40°C)
110 Ω
Accessories
S1-50°C
2.2kW/5.5A
S1-40°C
3.0kW/7.5A
43°C
45°C
45°C
4)
S1-50°C
1.1kW/3.1A
S1-40°C
1.5kW/4.0A
S1-30°C
1.5kW/4.8A
-3°C
0°C
0°C
slow-blowing
16 A
5)
Isc
[A]
RK5
x
10 A
(x)
x
10 A
(x)
x
R-10
(x)
x
10 A
-401-340-
-551-340-
2
3
4.0 kW
5.5 kW
5 hp
7 ½ hp
3 AC 380 ... 500 V, -20%/+10%, 47 Hz ... 63 Hz
8.9 A
11.7 A
8.0 A
10.3 A
3 AC 0 ... line voltage
9.5 A
12.5 A
8.5 A
11.0 A
b)
A
5.5 A
8.0 A
(S1-40°C)
(S1-40°C)
110 Ω
68 Ω
3.0kW/8.0A
4.0kW/11.8A
4.0kW/9.5A
5.5kW/12.5A
41°C
48°C
45°C
50°C
41°C
50°C
1.5kW/4.0A
1.5kW/5.3A
1.5kW/4.9A
2.2kW/6.9A
2.2kW/5.7A
3.0kW/8.4A
-20°C
1°C
-5°C
15°C
-15°C
5°C
General fuses (AC) (recommended)
16 A
20 A
UL-approved fuses (AC)
30 A
30 A
30 A
30 A
R-30
R-30
25 A
25 A
-751-340-
3
7.5 kW
10 hp
15.0 A
13.1 A
16.0 A
14.0 A
c)
d)
8.0 A
(S1-40°C)
68 Ω
4)
5.5kW/13.8A
7.5kW/16.0A
43°C
45°C
45°C
2.2kW/6.3A
3.0kW/7.9A
4.0kW/9.4A
-18°C
-5°C
-10°C
25 A
30 A
30 A
R-30
25 A
BU 0200 en-US-4920