Operation In Potentially Explosive Environments - Atex Zone 22 3D; Modification Of The Device For Compliance With Category 3D - nord NORDAC FLEX SK 200E Series User Manual

Table of Contents

Advertisement

Pos : 175.8 /Anleitungen/El ektr onik /FU und Starter/2. M ontage und Installation/ATEX und EAC EX ( SK 1xx E, SK 200E)/Betrieb i n ex plosi onsgefähr deter Umg ebung - AT EX Zone 22 3D _01 (Ü berschrift) [SK 1xx E / SK 2xx E] @ 22\mod_1528892785669_14638.doc x @ 2426747 @ 3 @ 1

2.6.1 Operation in potentially explosive environments - ATEX zone 22 3D

Pos : 175.9 /Anleitungen/El ektr onik /FU und Starter/2. M ontage und Installation/ATEX und EAC EX ( SK 1xx E, SK 200E)/Betrieb i n ex plosi onsgefähr deter Umg ebung - AT EX Zone 22 3D _02 [SK 1xx E / SK 2xx E] @ 22\mod_1528895961505_14638.doc x @ 2426795 @ @ 1
All of the conditions which must be observed for operation of the device in an explosion hazard
environment (ATEX) are summarized below.
Pos : 175.10 /Anl eitungen/Elektronik/FU und Starter/2. Montage und Installati on/AT EX und EAC EX (SK 1xx E, SK 200E)/M odi fizier ung des Gerätes z ur Ei nhaltung der Kategorie 3D - ATEX_01 [SK 1x xE / SK 2xx E] @ 58\m od_1605709415641_14638.docx @ 2693384 @ 4 @ 1
2.6.1.1

Modification of the device for compliance with category 3D

Only a specially modified device is permissible for operation in ATEX zone 22. This adaptation is only
made at the NORD factory. In order to use the device in ATEX zone 22, the diagnostic caps are
replaced with anodized oil inspection glasses, among other things.
Information
Possible damage caused by mechanical overload
Devices in series SK 2xxE and the permitted options are only designed for a degree of mechanical
stress that corresponds to a low impact energy of 4J.
Higher loads will lead to damage to or in the device.
Pos : 175.11 /Anl eitungen/Elektronik/FU und Starter/2. Montage und Installati on/AT EX und EAC EX (SK 1xx E, SK 200E)/M odi fizier ung des Gerätes z ur Ei nhaltung der Kategorie 3D - ATEX_02 [SK 2x xE] @ 19\m od_1505901677263_14638.docx @ 2365560 @ @ 1
The components needed for the modification are contained in an appropriately modified variable
frequency drive connection unit (SK TI4-...-EX).
Pos : 175.12 /Allgemei n/Allgemei ngültige M odul e/---------Seitenum bruch kom pakt --------- @ 13\m od_1476369695906_0.docx @ 2265496 @ @ 1
BU 0200 en-US-4920
2 Mounting and installation
( 1 ) Year of manufacture
( 2 ) Labelling of the device (ATEX)
II 3D Ex tc IIIB T125°C Dc X
IP55:
II 3D Ex tc IIIC T125°C Dc X
IP66:
Allocation:
Protection with "housing"
Procedure "A" zone "22" category 3D
IP55/IP66 rating (according to the device)
IP66 is required for conductive dust
Maximum surface temperature 125°C
Ambient temperature -20°C to +40°C
77