Potentiometers P1 And P2 And Diagnostic Leds - nord NORDAC SK 200E Manual

Hide thumbs Also See for NORDAC SK 200E:
Table of Contents

Advertisement

NORDAC SK 200E Manual
4.1.2

Potentiometers P1 and P2 and diagnostic LEDs

The enable signal (Start/Stop) is implemented with the external switch. The setpoint value can be fixed with
the integrated potentiometer P1. The potentiometer P2 is available for selection of the start-up and braking
ramps.
 
Diagnostic LEDs (4.1.2.1)
1
yellow
2
yellow
3
yellow
4
yellow
5
yellow
6
yellow
7
yellow
8
yellow
9
green
10
red
84
RJ12 
RS 232 
RS 485 
Digital output
Digital input 1
Digital input 2
Digital input 3
Digital input 4
Motor PTC
Brake chopper active
Mech. brake status
Bus Status 1
Bus Status 2
Subject to technical alterations
P1 / P2
Diagnostic 
LED‐FI 
 
LEDs
LED‐ASi
Potentiometer and LEDs (4.1.2.2)
P1
(continuous)
0%
P102/103
10%
0.2s
20%
0.3s
30%
0.5s
40%
0.7s
50%
1.0s
60%
2.0s
70%
3.0s
80%
5.0s
90%
7.0s
100%
10.0s
The function of P1 and P2 depends on DIP 4/5 (Section 4.1.1).
The function changes according to the setting.
As standard, P1 sets the setpoint value of 0-100% and P2 sets the
ramp from 0.2-7sec.
green
LED FI
red
green
LED AS-I
red
SK 200E, top view 
P2
(stepped)
P105
-
10Hz
1
P102/103
20Hz
2
0.2s
30Hz
3
0.3s
40Hz
4
0.5s
50Hz
5
0.7s
60Hz
6
1.0s
70Hz
7
2.0s
80Hz
8
3.0s
90Hz
9
5.0s
100Hz
10
7.0s
Ready / Load (flashing)
Error / Error number (flashing)
AS-Interface status (dual LED)
-
-
P104
2Hz
5Hz
10Hz
15Hz
20Hz
25Hz
30Hz
35Hz
40Hz
BU 0200 GB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents