VACON® NXP Advanced Safety Options
Operating Guide
Variable
Source/
type
SafetyFunction-
Firmware
ReachedWord
SafetyGeneralSta-
Firmware
tusWord
EstimatedShaft-
Firmware
Frequency
EstimatedShaft-
Firmware
FreqInvalid
140 | Danfoss A/S © 2021.06
Description
B1 = SS1
B2 = SS2
B3 = SQS
B4 = SSR
B5 = SLS1
B6 = SLS2
B7 = SLS3
B10 = SSM
B11 = SMS
Displays the reached status of the safety functions. Corresponds to the Reached signal of the
safety function.
0 = The safety function is not reached.
1 = The safety function is reached.
B0 = STO
B1 = SS1
B2 = SS2
B3 = SQS
B4 = SSR
B5 = SLS1
B6 = SLS2
B7 = SLS3
B10 = SSM
B11 = SMS
Displays various states of the Advanced safety option.
NOTE! The state is updated only for digital inputs and outputs that have a functionality as-
signed to them. Bits corresponding to unused digital inputs and outputs remain as "0" regard-
less of the actual state.
B0 = DIN1
B1 = DIN2
B2 = DIN3
B3 = DIN4
B4 = DOUT1
B5 = DOUT2
B6 = SSM_Above_Max_Limit
B7 = SSM_Below_Max_Limit
B8 = Acknowledge_Requested_DIN
B9 = Acknowledge_Requested_PLC
B10 = Acknowledge_Requested_ Drive
B11 = SS1_Ramp_Select
B12 = SS2_Ramp_Select
B13 = Reset_Requested_DIN
B14 = Reset_Requested_PLC
B15 = Reset_Requested_Drive
Displays the value of the estimated speed provided to the Advanced safety option.
If this value is other than 0, the Estimated Shaft Frequency is not currently being calculated and
provided to the Advanced safety option.
Operation and Maintenance
AQ319736045637en-000101 / DPD01798