Komatsu WA600-8 Operation & Maintenance Manual page 527

Wheel loader
Table of Contents

Advertisement

ATTACHMENTS AND OPTIONS
1.
Press the menu switch (1) on the standard screen.
2.
Press menu switch (1) and select "Load Meter" menu.
3.
Press UP switch (2) or DOWN switch (3) to select "Calibra-
tion", and press ENTER switch (4).
The screen changes to "Calibration" screen, and the mode
of calibration can be selected.
4.
Press UP switch (2) or DOWN switch (3) to select "Calibra-
tion Reset", and press ENTER switch (4).
5.
When the confirmation screen for Reset is displayed,
press ENTER switch (4) to reset or press RETURN switch
(5) to cancel resetting.
6.
After resetting, the default value of calibration data and
calibration load are displayed, and "*" is displayed beside
the calibration load.
LEARNING FUNCTION OF CALIBRATION
Performing the calibration several times can average the data and thereby suppress the effect of variation in the
calibration data.
SWITCH DISPLAY/NON-DISPLAY OF LOAD METER
Load meter can be set to Non-display when it is not in use.
HANDLE LOAD METER
6-65

Advertisement

Table of Contents
loading

Table of Contents