Komatsu WA600-8 Operation & Maintenance Manual page 218

Wheel loader
Table of Contents

Advertisement

EXPLANATION OF COMPONENTS
WHILE REGENERATION IS NOT BEING PERFORMED: SETTING FOR REGENER-
ATION DISABLE
(When the aftertreatment devices regeneration is not displayed on the standard screen)
1.
Press the menu switch on the standard screen.
2.
Press the menu switch to select "Aftertreatment Devices
Regeneration" menu screen, and "Aftertreatment Devices
Regeneration" menu screen is displayed.
3.
Select the regeneration disable and press ENTER switch.
The regeneration function is disabled and the regeneration
is not performed.
REMARK
When the regeneration is disabled, aftertreatment devices
regeneration disable pilot lamp (5) is displayed with hatch
on the standard screen.
The setting of the regeneration disable is canceled by turn-
ing the starting switch to OFF position. When the automat-
ic regeneration needs to be kept disabled, perform the
above procedure each time you start the engine.
During the regeneration to protect the system, even if the
regeneration disable is set, aftertreatment devices regen-
eration pilot lamp (2) may light up, but this does not indi-
cate abnormality. Also, during the regeneration to protect
the system, the regeneration disable cannot be operated.
When the regeneration is performed to protect the system,
the exhaust temperature is lower than that of when the re-
generation is performed to burn soot, and is almost the
same level as the normal exhaust gas temperature.
WHILE REGENERATION IS BEING PERFORMED: STOPPING REGENERATION
(When the aftertreatment devices regeneration display is lit on the standard screen)