Racal Instruments 2461 User Manual page 169

200mhz universal counter timer type c
Table of Contents

Advertisement

Note: In separate mode, Stop can occur before Start by up to 2ns in order to
ensure that 0ns is met.
Input Channels Commoned
START
on Input 1
STOP
on Input 1
Input Channels Separate
START
on Input 1
STOP
on Input 2
or
START
on Input 2
STOP
on Input 1
Trigger Slopes
Start:
Positive or Negative
Stop:
Positive or Negative
LSD
1ns
Resolution
± LSD ± 1ns RMS ± START TRIGGER ERROR
Accuracy
± RESOLUTION ± (TIMEBASE ERROR x TI) ± (TRIGGER LEVEL TIMING ERROR
A-10
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
± 2ns (DIFFERENTIAL CHANNEL DELAY ERROR
User Manual 2461 Type C
± STOP TRIGGER ERROR