Assignment of output signals
• The signals can be assigned to the open collector output terminals (2 terminals) and relay output terminal (1 terminal),
which are provided as the output terminals of the inverter. (The open collector output terminals are provided only with the
standard model.)
• The signals can be output via communication, or assigned to the extension terminals of the plug-in option (FR-A8AY or
FR-A8AR).
External output terminal
Terminal
Pr.
name
FR-E800
190
RUN
○
191
FU
○
192
A,B,C
○
193
NET Y1
—
194
NET Y2
—
195
NET Y3
—
196
NET Y4
—
313
DO0
—
314
DO1
—
315
DO2
—
316
DO3
—
317
DO4
—
318
DO5
—
319
DO6
—
320
RA1
—
321
RA2
—
322
RA3
—
○: Assignment/output available, ─: Assignment/output unavailable (no function)
*1
The communication protocol affects which terminal can be used. For details, refer to the Instruction Manual (Communication) or the Instruction
Manual of the communication option.
*2
Refer to the Instruction Manual of the option for details on the option output terminals.
Output signal list
• A function listed below can be set to each output terminal.
• Refer to the following table and set the parameters. (0 to 99, 200 to 299: Positive logic, 100 to 199, 300 to 399: Negative
logic)
Setting
Signal
Positive
Negative
name
logic
logic
0
100
RUN
1
101
SU
3
103
OL
4
104
FU
7
107
RBP
8
108
THP
11
111
RY
(physical terminal)
communication
FR-E800-
(SC)E
—
○
—
○
○
○
—
○
—
○
—
○
—
○
—
○
—
○
—
○
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Function
Output during operation when the inverter
Inverter running
output frequency reaches Pr.13 Starting
frequency or higher.
Output when the output frequency reaches
*1
Up to frequency
the set frequency.
Output while the stall prevention function
Overload warning
works.
Output when the output frequency reaches
Output frequency
the frequency set in Pr.42 (Pr.43 during
detection
reverse rotation) or higher.
Regenerative brake
Output when the regenerative brake duty
prealarm
reaches 85% of the setting of Pr.70.
Output when the cumulative electronic
thermal O/L relay value reaches 85% of the
Electronic thermal O/L
trip level. (The electronic thermal O/L relay
relay pre-alarm
function (E.THT/E.THM) is activated when
the value reaches 100%.)
Output when the reset process is completed
after powering ON the inverter or when the
Inverter operation ready
inverter is ready to start operation with the
start signal ON or during operation.
Option output terminal (physical
terminal)
Output via
*1
FR-A8AY
—
—
—
—
—
—
—
○
○
○
○
○
○
○
—
—
—
Operation
13. (M) Item and Output Signal for Monitoring
*2
FR-A8AR
—
—
—
—
—
—
—
—
—
—
—
—
—
—
○
○
○
Related
Refer to page
parameter
—
337
Pr.41
341
Pr.22, Pr.23,
295
Pr.66, Pr.154
Pr.42, Pr.43
341
Pr.70
484
Pr.9
276
—
337
13.6 Output terminal function selection
11
12
13
14
15
16
17
18
19
20
333