Setting
Signal
Positive
Negative
name
logic
logic
Inverter running and start
45
145
RUN3
command ON
During deceleration at
46
146
Y46
occurrence of power
failure
During PID control
47
147
PID
activated
48
148
Y48
PID deviation limit
Home position return
56
156
ZA
failure
During PM sensorless
57
157
IPM
vector control
60
160
FP
Position detection level
During position command
61
161
PBSY
operation
62
162
CPO
Rough match
Home position return
63
163
ZP
completed
64
164
Y64
During retry
70
170
SLEEP
PID output interruption
80
180
SAFE
Safety monitor output
81
181
SAFE2
Safety monitor output 2
82
182
Y82
BACnet binary output
Position control
84
184
RDY
preparation ready
90
190
Y90
Life alarm
Fault output 3 (Power-
91
191
Y91
OFF signal)
Energy saving average
92
192
Y92
value updated timing
93
193
Y93
Current average monitor
95
195
Y95
Maintenance timer
Function
Output while the inverter is running or while
the start command signal is ON.
Output when the power-failure deceleration
function is activated.
(The signal output is retained until the
function stops.)
Output during the PID control operation.
Output when the absolute deviation value
exceeds the limit value.
Output while the home position return error
warning occurs.
Output while the operation is performed
under PM sensorless vector control.
Output when the current position exceeds
the position detection judgment value (set in
Pr.1294 and Pr.1295).
Output while the position command
operation is performed.
Output when the remaining command
distance (before electronic gear) reaches
the Pr.510 setting value or less. (The
remaining distance can be calculated by
subtracting the position command (before
electronic gear) from the target position
(before electronic gear).)
Output when the home position return is
completed.
Output during retry operation.
Output while PID output suspension function
is activated.
Output while the safety stop function is
activated.
Output when no internal safety circuit failure
exists.
Enables output from the Binary Output
object for BACnet communication. This
signal can be assigned to Pr.192 only. (The
setting is available only for the FR-E800-
EPA and the FR-E800-SCEPA.)
Output when the servo-lock function is
working (the LX signal turns ON) and the
inverter is ready to operate.
Output when the life check function detects
the part approaching the end of its life.
Output when the Fault occurs due to an
inverter circuit fault or connection fault.
Switches between ON and OFF every time
the average energy saving is updated during
the energy saving monitoring. This signal
cannot be assigned to any of the relay
output terminal (Pr.192, Pr.320 to Pr.322).
Output in pulses for transmission of the
average current value and the maintenance
timer value. This signal cannot be assigned
to any of the relay output terminal (Pr.192,
Pr.320 to Pr.322).
Output when the value of Pr.503 reaches
the Pr.504 setting or higher.
Operation
parameter
Pr.261
Pr.127 to
Pr.134, Pr.575
to Pr.577
Pr.127 to
Pr.134,
Pr.553, Pr.554
Pr.71 to Pr.80,
Pr.998
Pr.1294 to
Pr.1297
Pr.510
Pr.65 to Pr.69
Pr.127 to
Pr.134, Pr.575
to Pr.577
Pr.549
Pr.198, Pr.255
to Pr.259,
Pr.506,
Pr.507, Pr.509
Pr.52, Pr.54,
Pr.158, Pr.891
to Pr.899
Pr.555 to
Pr.557
Pr.503, Pr.504
13. (M) Item and Output Signal for Monitoring
13.6 Output terminal function selection
Related
Refer to page
337
455
420
420
167
112
180
179
180
167
289
420
Instruction
Manual
(Functional
Safety)
Instruction
Manual
(Communication)
168
223
340
326
228
227
335
11
12
13
14
15
16
17
18
19
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800 seriesFr-e800Fr-e820-0008Fr-e840-0016Fr-e860-0017Fr-e820s-0008 ... Show all

Table of Contents