Mitsubishi Electric 800 Series Instruction Manual (Function page 372

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Setting
Signal
value
name
Pr.178
60
STF
61
STR
62
RES
65
X65
66
X66
67
X67
72
X72
74
X74
76
X76
87
X87
88
LSP
89
LSN
92
X92
9999
No function
○: Assignment available, ─: Assignment unavailable (no function)
 Adjusting the response of input terminals (Pr.699)
• Response of the input terminals (physical terminals) can be delayed in a range between 5 to 50 ms. (The following is the
operation example of the STF signal.)
ON
STF
Pr.699
9999
Pr.699
NOTE
• The Pr.699 setting is invalid (no filter) for the following signals.
— Input signals which are already in the ON state when the power is turned ON
— Input signals used for the PLC function
— Output stop (MRS) signal
FR-E800
Pr.180 to
Pr.185 to
Pr.179
Pr.184
Time
OFF
Pr.699
FR-E800-E
Pr.178
Pr.179
Pr.189
14. (T) Multi-Function Input Terminal Parameters
14.6 Input terminal function selection
FR-E800-
SCE
Pr.180 to
Pr.180 to
Pr.189
Pr.189
371
11
12
13
14
15
16
17
18
19
20