Digital source (monitor item) selection
• Select the digital sources (input/output signals) to be set to Pr.1038 to Pr.1045 from the following table. When a value
other than the ones in the following table is set, "0" (OFF) is applied for indication.
Setting
Signal
Pr.
value
name
0
—
—
*1
1
178
STF
*1
2
179
STR
*2
5
180
RL
*2
6
181
RM
*2
7
182
RH
*2
9
183
MRS
*2
11
184
RES
21
X0
—
22
X1
—
23
X2
—
24
X3
—
25
X4
—
26
X5
—
27
X6
—
28
X7
—
29
X8
—
30
X9
—
31
X10
—
32
X11
—
33
X12
—
34
X13
—
35
X14
—
36
X15
—
37
DY
—
*1
Fixed to OFF state in the safety communication model.
*2
Fixed to OFF state in the Ethernet model and safety communication model.
Trigger setting (Pr.1025, Pr.1035 to Pr.1037, Pr.1046, Pr.1047)
• Set the trigger generating conditions and the trigger target channels.
Pr.1025
setting
0
Tracing starts when inverter enters a fault status (protective function activated)
1
Tracing starts when analog monitor satisfies trigger conditions
2
Tracing starts when digital monitor satisfies trigger conditions
3
Tracing starts when either of analog or digital monitor satisfies trigger conditions (OR)
4
Tracing starts when both of analog or digital monitor satisfies trigger conditions (AND)
Remarks
Input status of an external
input terminal
For the details of the signals,
refer to
page
368.
Input status of a terminal of
the FR-A8AX (option)
Trigger generating conditions
Setting
Signal
Pr.
value
name
*2
101
190
RUN
*2
105
191
FU
106
A,B,C
192
121
DO0
313
122
DO1
314
123
DO2
315
124
DO3
316
125
DO4
317
126
DO5
318
127
DO6
319
128
RA1
320
129
RA2
321
130
RA3
322
Forward
152
—
running
Reverse
153
—
running
154
NET SU
—
155
NET OL
—
156
NET Y1
193
159
NET Y2
194
160
NET Y3
195
161
NET Y4
196
166
NET ALM
—
201
NET AU
—
202
NET STF
—
203
NET STR
—
204
NET RL
180
205
NET RM
181
206
NET RH
182
207
NET RT
—
208
NET MRS 183
NET
209
—
JOG2
210
NET X1
185
211
NET X2
186
212
NET RES
184
213
NET X3
187
214
NET X4
188
215
NET X5
189
Remarks
For the details of the signals,
refer to
page
332.
Output status of a terminal of
the FR-A8AY (option)
Output status of a terminal of
the FR-A8AR (option)
Output status of the signal
(via communication)
For the details of the signals,
refer to
page
332.
Input status of the signal (via
communication)
For the details of the signals,
refer to
page
368.
Selection of trigger
target channel
—
Pr.1035
Pr.1046
Pr.1035, Pr.1046
Pr.1035, Pr.1046
16. (A) Application Parameters
16.12 Trace function
11
12
13
14
15
16
17
18
19
20
463