Example of positioning operation by point tables (automatic continuous
positioning operation)
The following figure shows an operation example using the following point tables.
Target position
Point table
Upper
Lower
1
2
0
2
1
0
3
0
5000
Position command
speed
0.05s
(Pr.1222)
0
Target position
Servo ON
(LX)
STF
*2
ON
STR
*2
RM
*1
RL
*1
RH
*1
ON
Y36
ON
*1
Turn ON the start signal 5 ms or more after the point table selection signal is turned ON.
*2
After the start signal is turned ON, the ON state should be retained for 20 ms or longer.
NOTE
• During continuous operation, the position command speed drops to 0 in each point table operation before starting the next
point table operation.
• During continuous operation, no point table selection signal is received. Select the position feed length using point table before
turning ON the start command.
Return to home position during point table positioning
• Home position return is performed to match the command coordinates with the machine coordinates. Position control with
an absolute position cannot be performed until the home position is set.
• The returned home position can be set as point 0, and positioning operation is available using this point.
• Perform the home position return when the position command data and the current position data are within the range from
-2147483648 to 2147483647.
Home position return procedure
1.
Set parameters related to home position return.
• Set the home position return method (Pr.1282).
• Set the home position return speed (Pr.1283)
• Set the home position return shifting speed (Pr.511)
• Set the home position return shift amount if necessary. (Pr.1286 × 10000 + Pr.1285).
2.
Turn OFF the JOG signal and all point table selection signals.
• Turn OFF the RH, RM, RL and JOG signals.
3.
Turn ON the Pre-excitation/servo ON (LX) signal.
Maximum
Acceleration
speed (Hz)
time (s)
100.00
0.05
50.00
0.10
25.00
0.20
Point table 1
Point table 2
100.00Hz(Pr.4)
50.00Hz(Pr.5)
0.05s
(Pr.1223)
0.10s
(Pr.1226)
20000
30000(+10000)
ON
Deceleration
Auxiliary function
time (s)
1 (absolute position,
0.05
continuous)
11 (incremental position,
0.10
continuous)
10 (incremental position,
0.20
individual)
Point table 3
25.00Hz(Pr.6)
0.10s
0.20s
0.20s
(Pr.1227)
(Pr.1230) (Pr.1231)
35000(+5000)
ON
7.3 Simple positioning function by point tables
Point table 3
(Pr.1230) (Pr.1231)
0.20s
0.20s
Time
-25.00Hz(Pr.6)
30000(-5000)
ON
ON
ON
7. Position Control
1
2
3
4
5
6
7
8
9
10
167