Monitor item
Motor speed
Motor torque
Converter output
*1
voltage
Regenerative brake duty 0.1%
Electronic thermal O/L
relay load factor
Output current peak
value
Converter output voltage
peak value
Input power
*1
Output power
Load meter
Motor excitation current
Reference voltage output —
Motor load factor
Torque command
Torque current command 0.1%
Energy saving effect
PID set point
PID measured value
PID deviation
Motor thermal load factor 0.1%
Ideal speed command
Inverter thermal load
factor
PID measured value 2
PLC function analog
output
PID manipulated amount 0.1%
Dancer main speed
setting
*1
The inverter regards the output current which is less than the specified current level (5% of the rated inverter current) as 0 A. Therefore, each
readout of an output current and output power may show "0" if a too small-capacity motor is used as contrasted with the inverter capacity and the
output current falls below the specified value.
320
13. (M) Item and Output Signal for Monitoring
13.3 Monitor display selection for terminals FM and AM
Pr.54 (FM),
Increment and
Pr.158 (AM)
unit
setting
*3
6
1 r/min
0.1%
7
0.1 V
8
9
0.1%
10
0.01 A
11
0.1 V
12
0.01 kW
13
0.01 kW
14
0.1%
17
0.01 A
18
21
0.1%
24
0.1%
32
33
Increment and unit
vary depending on
50
the parameter
settings.
0.1%
52
0.1%
53
*2
0.1%
54
61
*3
65
0.01 Hz
0.1%
62
0.1%
67
0.1%
70
*2
91
*3
97
0.01 Hz
Terminal FM/AM
Negative
full-scale value
output
Pr.55 or the value
converted with the
Pr.37 or Pr.81
(Pr.454) value from
Pr.55.
Pr.866
200 V class: 400 V,
400 V class: 800 V,
575 V class: 1000 V
Brake duty decided
by Pr.30, Pr.70.
Electronic thermal O/
L relay (100%)
Pr.56
200 V class: 400 V,
400 V class: 800 V,
575 V class: 1000 V
Inverter rated power ×
2
Inverter rated power ×
2
Pr.866
Pr.56
200%
Pr.866
Pr.866
Inverter capacity
100%
100%
100%
Motor thermal
activation level
(100%)
Pr.55 or the value
converted with the
Pr.37 or Pr.81
(Pr.454) value from
Pr.55.
Inverter thermal
activation level
(100%)
100%
100%
100%
Pr.55 or the value
converted with the
Pr.37 or Pr.81
(Pr.454) value from
Pr.55.
Remarks
Terminal FM: 1440 pulse/s is
output.
Terminal AM: Output is 10 V.
For the information of the power
saving effect monitoring, refer to
page
326.
Refer to
page 429
for the PID
control.
Refer to
page 429
for the PID
control.
Enabled when Pr.414 ≠ "0".
Refer to
page 457
for the PLC
function.
Refer to
page 429
for the PID
control.
For details on dancer control, refer
to
page
436.