Mitsubishi Electric 800 Series Instruction Manual (Function page 314

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

Increment
Monitor item
and unit
Option input terminal
status 1 (for
*10
communication)
Option input terminal
status 2 (for
*10
communication)
Option output terminal
status (for
*10
communication)
Motor thermal load
0.1%
factor
Inverter thermal load
0.1%
factor
PTC thermistor
0.01 kΩ
resistance
Ideal speed command 0.01 Hz
PID measured value 2 0.1%
32-bit cumulative
1 kWh
energy (lower 16 bits)
32-bit cumulative
1 kWh
energy (upper 16 bits)
32-bit cumulative
0.01 kWh
energy (lower 16 bits)
32-bit cumulative
0.01 kWh
energy (upper 16 bits)
BACnet valid APDU
counter
1
PID manipulated
0.1%
amount
Dancer main set
0.01 Hz
speed
*1
The monitor code is used for the Mitsubishi inverter protocol, CC-Link, CC-Link IE TSN, CC-Link IE Field Network Basic, EtherNet/IP, and
PROFINET.
*2
The monitor code is used for the MODBUS RTU, MODBUS/TCP, and BACnet/IP.
*3
Indication with a minus sign is not possible via RS-485 communication (Mitsubishi inverter protocol or MODBUS RTU).
*4
To monitor the item on the LCD operation panel (FR-LU08) in the monitor mode, use Pr.774 to Pr.776 or the monitor function of the FR-LU08 for
setting.
*5
The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and accumulated again from 0.
*6
The actual operation time does not increase if the cumulative running time before power OFF is less than an hour.
*7
Since each readout of the output voltage and output current displayed on the operation panel is a 4-digit number, a value of more than "9999" is
displayed as "----".
*8
The inverter regards the output current which is less than the specified current level (5% of the rated inverter current) as 0 A. Therefore, each
readout of an output current and output power may show "0" if a too small-capacity motor is used as contrasted with the inverter capacity and the
output current falls below the specified value.
*9
The displayed item can be changed to the pulse after the electronic gear is set by using Pr.430 Pulse monitor selection. (Refer to
*10 Available when the plug-in option is connected.
Communication
Pr.
Monitor
Monitor
setting
*1
code 1
code 2
*13
H3A
40258
*14
H3B
40259
*15
H3C
40260
61
H3D
40261
62
H3E
40262
64
H40
40264
*16
65
H41
40265
67
H43
40267
H4D
40277
H4E
40278
H4F
40279
H50
40280
83
H53
40283
91
H5B
40291
*16
97
H61
40297
Negative
indication
*3
*2
(-)
The ON/OFF state of the input terminals X0 to X15 on
*13
the digital input option (FR-A8AX) is monitored via
communication.
The ON/OFF state of the input terminal DY on the digital
*14
input option (FR-A8AX) is monitored via
communication.
The ON/OFF state of the output terminals on the digital
*15
output option (FR-A8AY) or the relay output option (FR-
A8AR) is monitored via communication.
The accumulated heat value of the motor thermal O/L
relay is displayed.
The Motor overload trip (electronic thermal relay
function) (E.THM) occurs at 100%.
The accumulated heat value of the inverter thermal O/L
relay is displayed.
The Inverter overload trip (electronic thermal relay
function) (E.THT) occurs at 100%.
The PTC thermistor resistance is displayed when
Pr.561 PTC thermistor protection level ≠ "9999".
(The output voltage is displayed when Pr.561 = "9999".)
The speed command ideal to create a position
command.
The PID measured value is displayed while the PID
control is enabled (Pr.128 ≠ "0"), even if PID control
operating conditions are not satisfied. (Refer to
429.)
The upper or lower 16 bits of the 32-bit cumulative
energy is displayed on each indication.
Monitoring via communication is available.
The count of valid APDU detection is displayed.
(Available only for the FR-E800-EPA and FR-E800-
SCEPA.)
The PID control manipulated amount is displayed.
(Refer to
page
The set speed for main speed during the dancer control
operation is displayed.
13. (M) Item and Output Signal for Monitoring
13.2 Monitor item selection on operation panel or via communication
Description
429.)
page
11
12
13
14
15
16
17
page
18
19
20
175.)
313

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800 seriesFr-e800Fr-e820-0008Fr-e840-0016Fr-e860-0017Fr-e820s-0008 ... Show all

Table of Contents