Mitsubishi Electric 800 Series Instruction Manual (Function page 61

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Pr.100 to Pr.199
Function
Pr.
group
117
N020
118
N021
119
N022
N023
120
N024
121
N025
122
N026
123
N027
124
N028
125
T022
126
T042
127
A612
128
A610
129
A613
130
A614
131
A601
132
A602
133
A611
134
A615
145
E103
147
F022
150
M460
151
M461
152
M462
153
M463
154
H631
156
H501
157
M430
60
3. Parameters
3.2 Parameter list (by parameter number)
Pr.
Name
PU communication station
number [E800]
PU communication speed
[E800]
PU communication stop bit
length / data length [E800]
PU communication data
length [E800]
PU communication stop bit
length [E800]
PU communication parity
check [E800]
PU communication retry
count [E800]
PU communication check
time interval [E800]
PU communication waiting
time setting [E800]
PU communication CR/LF
selection [E800]
Terminal 2 frequency setting
gain frequency
Simple
Simple
Simple
Terminal 4 frequency setting
gain frequency
Simple
Simple
Simple
PID control automatic
switchover frequency
PID action selection
PID proportional band
PID integral time
PID upper limit
PID lower limit
PID action set point
PID differential time
PU display language
selection [E800]
Acceleration/deceleration
time switching frequency
Output current detection
level
Output current detection
signal delay time
Zero current detection level
Zero current detection time
Voltage reduction selection
during stall prevention
operation
Stall prevention operation
selection
OL signal output timer
Minimum
Setting range
setting
increments
0 to 31
1
48, 96, 192, 384, 576,
1
768, 1152
0, 1, 10, 11
0, 1
1
0, 1
0 to 2
1
0 to 10, 9999
1
0, 0.1 to 999.8 s, 9999 0.1 s
0 to 150 ms, 9999
1 ms
0 to 2
1
0 to 590 Hz
0.01 Hz
0 to 590 Hz
0.01 Hz
0 to 590 Hz, 9999
0.01 Hz
0, 20, 21, 40 to 43, 50,
51, 60, 61, 1000, 1001,
1
1010, 1011, 2000,
2001, 2010, 2011
0.1% to 1000%, 9999
0.1%
0.1 to 3600 s, 9999
0.1 s
0% to 100%, 9999
0.1%
0% to 100%, 9999
0.1%
0% to 100%, 9999
0.01%
0.01 to 10 s, 9999
0.01 s
0 to 7
1
0 to 590 Hz, 9999
0.01 Hz
0% to 400%
0.1%
0 to 10 s
0.1 s
0% to 400%
0.1%
0 to 10 s
0.01 s
1, 11
1
0 to 31, 100, 101
1
0 to 25 s, 9999
0.1 s
Initial
Refer
Customer
*1
value
to page
setting
Gr.1
Gr.2
*9
0
*9
192
1
*9
0
1
*9
2
*9
1
*9
0
*9
9999
*9
1
60 Hz 50 Hz
358
60 Hz 50 Hz
358
9999
420
420,
0
436
420,
100%
436
420,
1 s
436
420,
9999
436
420,
9999
436
420,
9999
436
420,
9999
436
200
9999
232
150%
344
0 s
344
5%
344
0.5 s
344
1
295
0
295
122,
0 s
295

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800 seriesFr-e800Fr-e820-0008Fr-e840-0016Fr-e860-0017Fr-e820s-0008 ... Show all