Pr.
Function
Pr.
group
464
B020
465
B021
466
B022
467
B023
468
B024
469
B025
470
B026
471
B027
472
B028
473
B029
474
B030
475
B031
476
B032
477
B033
478
B034
495
M500
496
M501
497
M502
498
A804
 Pr.500 to Pr.599
Pr.
Function
Pr.
group
502
N013
503
E710
504
E711
505
M001
506
E705
507
E706
509
E708
510
B196
511
B197
538
B015
Name
Digital position control
sudden stop deceleration
time
First target position lower 4
digits
First target position upper 4
digits
Second target position lower
4 digits
Second target position upper
4 digits
Third target position lower 4
digits
Third target position upper 4
digits
Fourth target position lower 4
digits
Fourth target position upper
4 digits
Fifth target position lower 4
digits
Fifth target position upper 4
digits
Sixth target position lower 4
digits
Sixth target position upper 4
digits
Seventh target position lower
4 digits
Seventh target position
upper 4 digits
Remote output selection
Remote output data 1
Remote output data 2
PLC function flash memory
clear
Name
Stop mode selection at
communication error
Maintenance timer
Maintenance timer warning
output set time
Speed setting reference
Display estimated main
circuit capacitor residual life
Display ABC relay contact
life
Display power cycle life
Rough match output range
Home position return shifting
speed
Current position retention
selection
Minimum
Setting range
setting
increments
0.01 to 360 s
0.01 s
0 to 9999
1
0 to 9999
1
0 to 9999
1
0 to 9999
1
0 to 9999
1
0 to 9999
1
0 to 9999
1
0 to 9999
1
0 to 9999
1
0 to 9999
1
0 to 9999
1
0 to 9999
1
0 to 9999
1
0 to 9999
1
0, 1, 10, 11
1
0 to 4095
1
0 to 4095
1
0, 9696 (0 to 9999)
1
Minimum
Setting range
setting
increments
0 to 2, 6
1
0 (1 to 9998)
1
0 to 9998, 9999
1
1 to 590 Hz
0.01 Hz
(0% to 100%)
1%
0% to 100%
1%
(0% to 100%)
0.01%
0 to 32767
1
0 to 400 Hz
0.01 Hz
1, 2, 11, 12, 9999
1
3.2 Parameter list (by parameter number)
Initial
Refer
Customer
*1
value
to page
setting
Gr.1
Gr.2
0.01 s
163
0
163
0
163
0
163
0
163
0
163
0
163
0
163
0
163
0
163
0
163
0
163
0
163
0
163
0
163
0
347
0
347
0
347
0
457
Initial
Refer
Customer
*1
value
to page
setting
Gr.1
Gr.2
*9
0
0
227
9999
227
60 Hz 50 Hz
308
100%
223
100%
223
100%
223
0
179
0.5 Hz
163
9999
182
3. Parameters
1
2
3
4
5
6
7
8
9
10
69