Extended Parameter Display And User Group Function - Mitsubishi Electric 800 Series Instruction Manual (Function

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

9.14
Extended parameter display and user group
function
Use this parameter to select a group of parameters to be displayed on the operation panel.
Pr.
160
User group read
E440
selection
172
User group registered
E441
display/batch clear
173
User group registration
E442
174
User group clear
E443
*1
The read value is always "9999".
 Display of simple mode parameters and extended parameters (Pr.160)
• When Pr.160 = "9999", only the simple mode parameters can be displayed on the operation panel. (For the simple mode
parameters, refer to the parameter list on
• With the initial value (Pr.160 = "0", simple mode parameters and extended parameters can be displayed.
NOTE
• When a plug-in option in installed on the inverter, the option parameters can also be read.
• Every parameter can be read regardless of the Pr.160 setting when reading parameters via communication.
• When the LCD operation panel (FR-LU08) or parameter unit (FR-PU07) is installed, Pr.15 Jog frequency, Pr.16 Jog
acceleration/deceleration time, C42 (Pr.934) PID display bias coefficient, C43 (Pr.934) PID display bias analog value,
C44 (Pr.935) PID display gain coefficient, C45 (Pr.935) PID display gain analog value, and Pr.991 PU contrast
adjustment are displayed as simple mode parameters.
 User group function (Pr.160, Pr.172 to Pr.174)
• The user group function is a function for displaying only the parameters required for a setting.
• A maximum of 16 parameters from any of the parameters can be registered in a user group. When Pr.160 = "1", reading/
writing is enabled only for the parameters registered in user groups. (Parameters not registered in user groups can no
longer be read.)
• To register a parameter in a user group, set the parameter number in Pr.173.
• To clear a parameter from a user group, set the parameter number in Pr.174. To batch clear all the registered parameters,
set Pr.172 = "9999".
218
9. (E) Environment Setting Parameters

9.14 Extended parameter display and user group function

Name
Initial value
0
0
*1
9999
*1
9999
page
Setting range
9999
Only simple mode parameters are displayed.
0
Displays simple mode and extended parameters.
1
Only parameters registered in user groups are displayed.
Displays the number of parameters that are registered in the
(0 to 16)
user groups. (Read-only)
9999
Batch clear of user group registrations
0 to 1999, 9999
Sets the parameter number to register for the user group.
0 to 1999, 9999
Sets the parameter number to clear from the user group.
55.)
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800 seriesFr-e800Fr-e820-0008Fr-e840-0016Fr-e860-0017Fr-e820s-0008 ... Show all

Table of Contents