Mitsubishi Electric 800 Series Instruction Manual (Function page 112

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

• Perform the offline auto tuning (Pr.96). (Refer to
• Select the online auto tuning (Pr.95). (Refer to
NOTE
• To perform driving in a better accuracy, perform offline auto tuning, then set the online auto tuning, and select Real sensorless
vector control.
• Under this control, rotations are more likely to be uneven than under V/F control. (This control method is not suitable for
grinder, wrapping machine, etc., which require even rotation at a low speed.)
• When the inverter is operated with a surge voltage suppression filter (FR-ASF-H/FR-BMF-H) installed between the inverter
and the motor, the output torque may decrease.
 Keeping the motor speed constant when the load fluctuates (speed
control gain)
Pr.
Name
Speed control gain
89
(Advanced magnetic flux
G932
vector)
569
Second motor speed
G942
control gain
• Use Pr.89 to keep the motor speed constant during variable load operation.
(This parameter is useful to make adjustments on the motor speed after replacing a conventional model with an FR-E800
series model.)
 Driving two motors under Advanced magnetic flux vector control
• Turning ON the Second function selection (RT) signal enables the second motor operation.
• Set a second motor in Pr.450 Second applied motor. (In the initial setting, "9999" (no second applied motor) is selected.
Refer to
page
380.)
Function
Applied motor
Motor capacity
Number of motor poles
Speed control gain (Advanced magnetic flux
vector)
Control method selection
NOTE
• The RT signal is a Second function selection signal. The RT signal also enables other second functions. (Refer to
To input the RT signal, set "3" in any parameter from Pr.178 to Pr.189 (Input terminal function selection) to assign the
function.
• Changing the terminal assignment using Pr.178 to Pr.189 (Input terminal function selection) may affect the other functions.
Set parameters after confirming the function of each terminal.
Parameters referred to
Pr.71, Pr.450 Applied
motorpage 380
Pr.800, Pr.451 Control method
selectionpage 104
page
385.)
page
402.)
Initial
Setting
value
range
Makes adjustments to keep the motor speed constant during variable load
0% to 200%
operation under Advanced magnetic flux vector control. The reference
9999
value is 100%.
9999
The gain set by Pr.71. (The gain set in accordance with the motor.)
Makes adjustments to keep the second motor speed constant during
0% to 200%
variable load operation under Advanced magnetic flux vector control. The
9999
reference value is 100%.
9999
The gain set by Pr.450. (The gain set in accordance with the motor.)
Speed
RT signal-ON (second motor)
Pr.450
Pr.453
Pr.454
Pr.569
Pr.451
Description
RT signal-OFF (first motor)
Pr.71
Pr.80
Pr.81
Pr.89
Pr.800
4.3 Selecting the Advanced magnetic flux vector control
1
2
3
4
5
6
7
8
9
10
page
374.)
111
4. Control Method

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-e800 seriesFr-e800Fr-e820-0008Fr-e840-0016Fr-e860-0017Fr-e820s-0008 ... Show all

Table of Contents