Input Terminal Function Selection - Mitsubishi Electric 800 Series Instruction Manual (Function

Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

14.6

Input terminal function selection

Use the following parameters to select or change the input terminal functions.
Pr.
Name
178
STF/DI0 terminal
*1
function selection
T700
179
STR/DI1 terminal
*1
function selection
T701
180
RL terminal function
T702
selection
181
RM terminal function
T703
selection
182
RH terminal function
T704
selection
183
MRS terminal
T709
function selection
184
RES terminal
T711
function selection
185
NET X1 input
T751
selection
186
NET X2 input
T752
selection
187
NET X3 input
T753
selection
188
NET X4 input
T754
selection
189
NET X5 input
T755
selection
Pr.
Name
699
Input terminal filter
*1
T740
*1
Available for the standard model and the Ethernet model only.
*2
The setting range differs depending on the model. For more information, refer to the parameters available for each signal.
 Input terminal function assignment
• Signals can be input to the inverter by using physical terminals (except for the FR-E800-SCE) or via communication.
• Use the following parameters to assign functions to input terminals. Check the terminal available for each parameter.
Terminal
Pr.
name
178
STF/DI0
179
STR/DI1
180
RL
181
RM
182
RH
183
MRS
184
RES
185
NET X1
186
NET X2
187
NET X3
188
NET X4
189
NET X5
368
14. (T) Multi-Function Input Terminal Parameters
14.6 Input terminal function selection
Initial
value
60
STF (Forward rotation command)
61
STR (Reverse rotation command)
0
RL (Low-speed operation command)
1
RM (Middle-speed operation command)
2
RH (High-speed operation command)
24
MRS (Output stop)
62 [E800] RES (Inverter reset)
9999
[E800-
No function
(SC)E]
9999
No function
9999
No function
9999
No function
9999
No function
9999
No function
Initial
Setting range
value
5 to 50 ms
9999
9999
External input terminal (physical terminal)
FR-E800
FR-E800-E
○ (STF)
○ (DI0)
○ (STR)
○ (DI1)
Initial signal
0 to 5, 7, 8, 10, 12 to 16, 18, 23 to 27, 30, 37, 42,
43, 46, 47, 50, 51, 60, 62, 65 to 67, 72, 74, 76,
87 to 89, 92, 9999
0 to 5, 7, 8, 10, 12 to 16, 18, 23 to 27, 30, 37, 42,
43, 46, 47, 50, 51, 61, 62, 65 to 67, 72, 74, 76,
87 to 89, 92, 9999
0 to 5, 7, 8, 10, 12 to 16, 18, 23 to 27, 30, 37, 42,
43, 46, 47, 50, 51, 62, 65 to 67, 72, 74, 76, 87 to
89, 92, 9999
0 to 4, 8, 13 to 15, 18, 23, 24, 26, 27, 30, 37, 42,
43, 46, 47, 50, 51, 72, 74, 76, 87 to 89, 92, 9999
Set the time delay for the input terminal response.
No filter for the input terminal
Input via
communication
FR-E800-SCE
Forward rotation
command only
Reverse rotation
command only
Setting range
*2
Description
*1