 Setting for the V/F control by selecting PM parameter initialization on the
operation panel ("PM")
• When the control method is changed from PM sensorless vector control to V/F control, all the parameter settings required to
drive an induction motor are automatically set. (Refer to
The following shows the procedure to change the control method from PM sensorless vector control to V/F control by selecting
PM parameter initialization on the operation panel.
Operating procedure
1.
Turning ON the power of the inverter
The operation panel is in the monitor mode.
2.
Changing the operation mode
Press the PU/EXT key to choose the PU operation mode.
The PU LED turns ON.
3.
Selecting the parameter setting mode
Press the MODE key to choose the parameter setting mode.
The PRM LED is ON.
4.
PM parameter initialization
Turn the setting dial or press the UP/DOWN key until "PM" (PM parameter initialization) appears.
5.
Displaying the set value
Press the SET key to read the present set value.
The value set in Pr.998 is displayed.
6.
Changing the setting value
Turn the setting dial or press the UP/DOWN key to change the value to "0", and the SET key to confirm it.
"0" blinks. The setting is completed.
NOTE
• If PM parameter initialization is selected on the operation panel to set V/F control, the setting of Pr.998 PM parameter
initialization is also changed automatically.
• The changed parameter settings are the same as those when Pr.998 = "0".
114
4. Control Method
4.4 Selecting the PM sensorless vector control
page
112.)