• To input the X92 signal, set "92" in any parameter from Pr.178 to Pr.189 (Input terminal function selection) to assign
the function to a terminal.
• The X92 signal is a normally closed input (NC contact input) when it is input via an external input terminal, and a normally
open input (NO contact input) when it is input via communication.
• "PS" is displayed on the operation panel during activation of the emergency stop function.
Deceleration
by an emergency stop
Output frequency
Start signal
ON
X92
ON
OFF
NOTE
• The X92 signals can be assigned to an input terminal by setting Pr.178 to Pr.189 (Input terminal function selection).
Changing the terminal assignment may affect other functions. Set parameters after confirming the function of each terminal.
Parameters referred to
Pr.3 Base
frequencypage 470
Pr.10 DC injection brake operation
Pr.29 Acceleration/deceleration pattern
Pr.125, Pr.126 (frequency setting gain
Pr.178 to Pr.189 (Input terminal function
Normal
acceleration
Time
OFF
ON
ON
frequencypage 476
selectionpage 238
frequency)page 358
selection)page 368
10. (F) Settings for Acceleration/Deceleration