 Registering a parameter in a user group (Pr.173)
• To register Pr.3 in a user group
Operating procedure
1.
Power ON
Make sure the motor is stopped.
2.
Changing the operation mode
Press the PU/EXT key to choose the PU operation mode. The PU LED turns ON.
3.
Selecting the parameter setting mode
Press the MODE key to choose the parameter setting mode. (The parameter number read previously appears.)
4.
Selecting a parameter
Turn the setting dial or press the UP/DOWN key until "P.173" (Pr.173) appears.
5.
Parameter read
Press the SET key. "9999" appears.
6.
Parameter registration
Turn the setting dial or press the UP/DOWN key until "3" (Pr.3) appears. Press the SET key to register the
parameter.
"3" blinks.
To continue adding parameters, repeat steps 5 and 6.
9. (E) Environment Setting Parameters
9.14 Extended parameter display and user group function
1
2
3
4
5
6
7
8
9
10
219