10.6 Device Range that Can Be Set

The device ranges of controller that can be used for GOT
are as follows.
Note that the device ranges in the following tables are the
maximum values that can be set in GT Designer3.
The device specifications of controllers may differ
depending on the models, even though belonging to the
same series.
Please make the setting according to the specifications of
the controller actually used.
When a non-existent device or a device number outside
the range is set, other objects with correct device settings
may not be monitored.
Setting item
Item
Set the device name, device number, and bit number.
The bit number can be set only when specifying the bit of
word device.
Device
Memory
Set the memory number (None, 0 to 7) of the
*1
device to be monitored.
No.
Displays the device type and setting range which are
Information
selected in [Device].
Set the monitor target of the set device.
Select this item when writing data to all the
indicating controllers connected.
During monitoring, the indicating controller which
is set for [Host Address] of the communication
detail setting is monitored.
All
(When writing the data in numerical input, the
data is written to all connected indicating
controllers during input, and the indicating
controller that is set for [Host Address] is
monitored during other than input (displaying).)
Network
Select this item when monitoring the indicating
controller of the specified station No.
After selecting, set the station No. of the
indicating controller in the following range.
0 to 94:
Station
No.
95:
100 to 115:
Description
To monitor the indicating controller
of the specified station No.
Same as the setting of [All].
To specify the station No. of the
indicating controller to be
monitored by the value of GOT
*2
data register (GD).
10. CONNECTION TO SHINKO TECHNOS INDICATING CONTROLLER
*1
The device name is displayed as follows when the memory
number (0 to 7) is set.
Memory No.
None
0
1
2
3
4
5
6
7
*2
The following shows the relation between station numbers of
the indicating controller and the GOT data register.
Station
GOT data register (GD)
No.
100
GD10
101
GD11
:
:
114
GD24
115
GD25
10.6.1 SHINKO indicating controller
(Shinko Technos Controller)
Device name
Setting range
Specified bit of the following
*1
Word device bit
word devices
Data item (..)
..0001 to ..7901
*1
As bit specification of a word device is performed after the
GOT reads the value, do not change the value with the
indicating controller during this period.
10.6 Device Range that Can Be Set
Displayed device name
Device Number
M0/Device Number
M1/Device Number
M2/Device Number
M3/Device Number
M4/Device Number
M5/Device Number
M6/Device Number
M7/Device Number
Setting range
0 to 94
(If setting a value
outside the range
above, a device range
error occurs.)
Device No.
representation
-
Hexadecimal
10 - 15
9
10
11
12
13
14
15

Advertisement