14.4 GOT Side Settings
14.4.1 Setting communication
interface (Communication
settings)
Set the channel of the equipment to be connected to the
GOT.
2.
1.
Select [Common]
[Controller Setting] from the
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: PANASONIC
• Controller Type: Set the option according to the
Controller Type to be connected.
• PANASONIC MINAS-A4 series
• PANASONIC MINAS-A5 series
• I/F: Interface to be used
• Driver: PANASONIC MINAS
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.
14.4.2 Communication detail settings
Click the [OK] button when settings are completed.
POINT
POINT
POINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
1.1.2 I/F communication setting
14.4.2 Communication detail settings
Make the settings according to the usage environment.
3.
Item
4.
Transmission
Speed
Data Bit
Click!
Stop Bit
Parity
Retry
Timeout
*1
Time
Host Address
Delay Time
POINT
POINT
POINT
(1) Communication interface setting by the Utility
(2) Precedence in communication settings
14. CONNECTION TO PANASONIC SERVO AMPLIFIER
Description
Set this item when change the
transmission speed used for
communication with the connected
equipment.
(Default: 9600bps)
Set this item when change the data
length used for communication with the
connected equipment.
(Default: 8bits)
Specify the stop bit length for
communications.
(Default: 1bit)
Specify whether or not to perform a parity
check, and how it is performed during
communication.
(Default: None)
Set the number of retries to be performed
when a communication error occurs.
(Default:3times)
Set the time period for a communication
to time out.
(Default: 3sec)
Specify the station No. of the servo
amplifier to connect the GOT.
(Default: 0)
Set this item to adjust the transmission
timing of the communication request from
the GOT.
(Default: 0ms)
The communication interface setting can be
changed on the Utility's [Communication Settings]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
User's Manual of GOT used.
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
14.4 GOT Side Settings
9
10
11
Range
9600bps,
19200bps,
38400bps,
57600bps,
12
115200bps
7bit/8bit
1bit/2bit
13
None
Even
Odd
0 to 5times
3 to 30sec
14
0 to 31
0 to 300ms
15
14 - 9

Advertisement