4.2.10 GOT Side Settings

Setting communication interface
(Communication settings)
Set the channel of the equipment to be connected to
the GOT.
2.
1.
Select [Common]
[Controller Setting] from the
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: OMRON
• Controller Type: Set the option according to the
Controller Type to be connected.
• OMRON SYSMAC
• OMRON SYSMAC CS/CJ
• I/F: Interface to be used
• Driver: OMRON SYSMAC
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.
4.2.10
Communication detail settings
Click the [OK] button when settings are completed.
POINT
POINT
POINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
1.1.2 I/F communication setting
Communication detail settings
Make the settings according to the usage environment.
3.
4.
Transmission Speed
Data Bit
Click!
Stop Bit
Parity
Retry
Timeout Time
Host Address
Delay Time
POINT
POINT
POINT
(1) Communication interface setting by the Utility
(2) Precedence in communication settings
4. CONNECTION TO OMRON PLC
Item
Description
Set this item when change the
transmission speed used for
communication with the
connected equipment.
(Default: 19200bps)
Set this item when change the
data length used for
communication with the
connected equipment.
(Default: 7bits)
Specify the stop bit length for
communications.
(Default: 2bits)
Specify whether or not to
perform a parity check, and
how it is performed during
communication.
(Default: Even)
Set the number of retries to be
performed when a
communication error occurs.
(Default: 0time)
Set the time period for a
communication to time out.
(Default: 3sec)
Specify the host address
(station No. of the PLC to
which the GOT is connected)
in the network of the GOT.
(Default: 0)
Set this item to adjust the
transmission timing of the
communication request from
the GOT.
(Default: 0ms)
The communication interface setting can be
changed on the Utility's [Communication Settings]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following
manual.
User's Manual of GOT used.
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
4.2 Serial Connection
1
2
3
Range
4800bps,
9600bps,
19200bps,
38400bps,
57600bps,
115200bps
4
7bit (fixed)
2bit (fixed)
Even (fixed)
5
0 to 5times
3 to 30sec
0 to 31
6
0 to 300 (ms)
7
8
4 - 23