M:N function
The M:N function is operated via the "Control unit management" option.
Prerequisite: Configuration via the NETNAMES.INI file
References:
/IAD/ 840D Commissioning Manual
The channel menu is selected using the "Channel switchover" softkey. Use the horizontal
softkeys to select a channel group (HMI Embedded: max. 8, HMI Advanced: max.
24 channel groups); up to eight connections to channels in different NCUs can be set up in
one channel group. The "Channel menu" display shows all the current connections and the
associated symbol names.
Note
If errors occur during power up (if, for example, connection setup fails), see Section "Power
up".
2.1.3.3

Configurability

2 control units: 1 NCU
The diagram below illustrates the connection between two control units and one NCU. In this
case, there is a fixed assignment between the MCP and the NCU.
Figure 2-4
The control units, NCU and machine control panel are all either connected to the OPI bus or
the MPI bus. A homogenous network must be provided with respect to these components.
The illustrated configuration enables a large machine tool to be equipped with a control unit
on both the front and rear sides, for example.
Extended Functions
Function Manual, 01/2008, 6FC5397-1BP10-3BA0
Several Operator Panels on Several NCUs, Distributed Systems (B3)
Example configuration (M:N in the ratio 2:1)
2.1 Brief Description