Siemens SINUMERIK 840D sl Function Manual page 50

Extended functions
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Digital and analog NCK I/Os (A4)
1.2 NCK I/O via PLC
Table 1-2
Examples of digital analog-value representation
Resolution
Bit number
Significance of the bits
14-bit analog value
12-bit analog value
For the resolutions and rating ranges of the analog input/output modules used, see:
References:
/PHD/ SINUMERIK 840D Configuration Manual NCU(HW)
/S7H/ SIMATIC S7-300 Software Installation Manual, Technology Functions.
Examples
Here are two examples of digital analog-value representation for a rating range of 10 V and
14-bit resolution.
Example 1:
Analog value:
Magnitude (decimal number):
Magnitude (pure binary number):
Word (pure binary number):
Word (hexadecimal number):
Example 2:
Analog value:
Magnitude (decimal number):
Magnitude (pure binary number):
Two's complement:
Word (pure binary number):
Word (hexadecimal number):
50
Binary analog value
High byte
15
14
13
12
11
SG
2
2
2
2
14
13
12
0
1
1
1
1
0
1
1
1
1
Low byte
10
9
8
7
2
2
2
2
11
10
9
8
7
0
0
1
1
0
0
1
1
9.5 V
7782 = j9.5(V)j:10(V) * 8192
0111 1001 1001 10
0111 1001 1001 1000
7998
-4.12 V
3375 = j-4.12(V)j:10(V) * 8192
0011 0100 1011 11
1100 1011 0100 01
1100 1011 0100 0100
CB44
6
5
4
3
2
2
2
2
6
5
4
3
0
0
1
1
0
0
1
0
Function Manual, 01/2008, 6FC5397-1BP10-3BA0