9.2.2

Generation of cam signals with gated output

General information
The plus and minus cam output signals are gated in the case of:
● timer-controlled cam signal output to the four onboard outputs on the NCU
● output to the NCK I/O devices if the 2nd byte in the following machine data was not
Linear axes
Figure 9-5
Extended Functions
Function Manual, 01/2008, 6FC5397-1BP10-3BA0
specified (= "0"):
MD10470 SW_CAM_ASSIGN_FASTOUT_2
to
MD10473 SW_CAM_ASSIGN_FASTOUT_4
Position switching signals for linear axis (minus cam < plus cam)
Software cams, position switching signals (N3)
9.2 Cam signals and cam positions