Several Operator Panels on Several NCUs, Distributed Systems (B3)
2.15 Examples
Active/passive operating mode
An online operator panel can operate in two different modes:
Active mode: Operator can control and monitor
Passive mode: Operators sees header information and the "passive" identifier.
MCP switchover
As an option, an MCP assigned to the operator panel can be switched over at the same
time.
2.15.2.2

Description of operational sequences (details)

Introduction
The operational sequences are described using identifiers for defined, logical functions
(example: OFFL_REQ_OP/ OK) whose programming application has been described earlier
in this section. The functions are coded in accordance with Section "Defined logical
functions/defines". The functions store values in the interface which can be addressed from
the PLC and the HMI. An operator panel utilizes the online-request interface while competing
for the use of an online interface. Operator panels which are already linked to an NCU utilize
one of the two available online interfaces. Details of these interfaces can be found in Section
"Signal descriptions" and in
References: Lists
In order to illustrate complete operating sequences, the description covers HMI activities
which cannot be influenced as well as modifiable PLC activities.
Operator panel sends request
If the operator panel is already linked online to an NCU (online NCU) and would like to
communicate with another NCU (target NCU), it must first notify the PLC of the online NCU
that it wishes to switch over to the target NCU.
It sends the offline request OFFL_REQ_OP/ OK to the online PLC.
OFFL_CONF_OP/OK:
Online PLC has received the offline request. HMI can now send a request to the target PLC.
OFFL_CONF_OP/PLC_LOCKED
Online PLC has received the offline request. The operator panel switchover is disabled in the
HMI-PLC interface. The operator panel cannot link up with another NCU and must remain
online.
On receipt of the positive acknowledgement OFFL_CONF_OP/OK, the operator panel sends
its online request to the target PLC of the relevant NCU by transmitting its
identification
Client identification
(ONL_REQUEST DB19, DBW100)
198
.
: Unique HMI identifier comprising bus type and bus address.
client
Function Manual, 01/2008, 6FC5397-1BP10-3BA0