Punching and Nibbling (N4)
10.3 Activation and deactivation
SPIF2
Activation of second punch interface
SPIF2 activates the second punch interface, i.e. the stroke is controlled via the second pair
of high-speed I/Os (see machine data MD26004 and MD26006).
Programming example:
:
:
N170 SPIF1 X100 PON
:
:
:
:
N180 X800 SPIF2
:
:
:
N190 SPIF1 X700
:
10.3.2

Functional expansions

Alternate interface
Machines that alternately use a second punching unit or a comparable medium can be
switched over to a second I/O pair.
The second I/O pair can be defined via the following machine data:
MD26004 $MC_NIBBLE_PUNCH_OUTMASK
MD26006 $MC_NIBBLE_PUNCH_INMASK
The interface is switched by command SPIF1 or SPIF2.
Full punching/nibbling functionality is available on both interfaces.
720
;
At the end of the block, a stroke is initiated at
;
the first high-speed output. The "Stroke active"
;
signal is monitored at the first input.
;
The second stroke is initiated at the second high-
;
speed output. The "Stroke active" signal is
;
monitored at the second input.
;
All further strokes are controlled with the first
;
interface.