[param MMC_1]
mmc_typ
mmc_bustyp
mmc_address
mstt_address
name
start_mode
Description of NCU components
[param NCU_1]
type = NCU_572 ; NCU type
nck_address = 20 ; Address j of NCU component on the bus
plc_address = 20 ; Address p of PLC component on the bus
name = NCU1 ; name of NCU
[param NCU_2]
type = NCU_572 ; NCU type
nck_address = 21 ; Address j of NCU component on the bus
plc_address = 21 ; Address p of PLC component on the bus
name = NCU2 ; name of NCU
[param NCU_3]
type = NCU_572 ; NCU type
nck_address = 22 ; Address j of NCU component on the bus
plc_address = 22 ; Address p of PLC component on the bus
name = NCU3 ; name of NCU
[param NCU_4]
type = NCU_572 ; NCU type
nck_address = 23 ; Address j of NCU component on the bus
plc_address = 23 ; Address p of PLC component on the bus
name = NCU4 ; name of NCU
; End of descriptive entry
Extended Functions
Function Manual, 01/2008, 6FC5397-1BP10-3BA0
Several Operator Panels on Several NCUs, Distributed Systems (B3)
= 40
; = 0100 0000: HMI is server and main control panel
= OPI
; Bus the HMI is attached to
= 10
; HMI address
= 6
; Address of the MCP to be switched simultaneously
= MMC_LINKS
; Name of operator panel
= ONLINE
; HMI is connected to the DEFAULT NCU in online
; mode on power up in accordance with channel data,
; see below
2.15 Examples