ErrorMMC : BOOL ; // Error detection HMI
END_VAR
Explanation of the formal parameters
The following table shows all formal parameters of function FB9
Table 2-8
Formal parameters of FB9
Signal
Type
Ack
I
OPMixedMode
I
AktivEnable
I
MCPEnable
I
Alarm1
O
Alarm2
O
Alarm3
O
Alarm4
O
Alarm5
O
Alarm6
O
Report
O
ErrorMMC
O
Note
The user program must call the block. The user must provide an instance DB with any
number for this purpose. The call is not multi-instance-capable.
Extended Functions
Function Manual, 01/2008, 6FC5397-1BP10-3BA0
Several Operator Panels on Several NCUs, Distributed Systems (B3)
Type
Comment
BOOL
Acknowledge alarms
BOOL
Hybrid operation with non M:N-capable OP
BOOL
Activate operator panel active/passive switchover
TRUE = Operator panel can be switched to active/passive.
FALSE = Operator panel cannot be switched to active and remains in its current
state.
BOOL
Activate MCP switchover
TRUE = MCP is switched over with operator panel
FALSE: = MCP is not switched over with operator panel.
BOOL
Alarm: Error in PCU bus address, bus type!
BOOL
Alarm: No confirmation PCU1 offline!
BOOL
Alarm: PCU1 is not going offline!
BOOL
Alarm: No confirmation PCU2 offline!
BOOL
Alarm: PCU2 is not going offline!
BOOL
Alarm: Requesting PCU is not going online!
BOOL
Message: Sign-of-life monitoring
BOOL
Error detection HMI