Positioning Axes (P2)
11.5 Programming
11.5.2
Revolutional feed rate in external programming
The two following setting data can be used to specify that the revolutional feed rate of a
positioning axis should be derived from another rotary axis/spindle:
SD43300 $SA_ASSIGN_FEED_PER_REV_SOURCE(revolutional feed rate for position
axes/spindles)
SD42600 JOG_FEED_PER_REV_SOURCE (control of revolutional feed rate in JOG)
The following settings are possible:
Value
0
>0
-1
-2
-3
776
Description
No revolutional feed rate selected
The revolutional feed rate is derived from the round axis/spindle with the machine axis
index specified here.
The revolutional feed rate is derived from the master spindle of the channel in which the
axis/spindle is active.
The revolutional feed rate is derived from the rotary axis/spindle with the machine axis
index 0.
The revolutional feed rate is derived from the master spindle of the channel in which the
axis/spindle is active. No revolutional feed rate is selected if the master spindle is at a
standstill.