General Setup - ZyXEL Communications GS1920v2 Series User Manual

8/24/48-port gbe smart managed switch
Hide thumbs Also See for GS1920v2 Series:
Table of Contents

Advertisement

Table 13 Basic Setting > System Info (continued)
L ABEL
Temperature
(C)
Current
MAX
MIN
Threshold
Status
Fan Speed
(RPM)
Current
MAX
MIN
Threshold
Status
Voltage(V)
Current
MAX
MIN
Threshold
Status
8.3 G e ne ra l Se tup
Use this screen to configure general settings such as the system name and time. Click
G e ne ra l Se tup
Chapter 8 Basic Setting
DESC RIPT IO N
,
and
refer to the location of the temperature sensors on the Switch printed
BO ARD
MAC
PHY
circuit board.
This shows the current temperature at this sensor.
This field displays the maximum temperature measured at this sensor.
This field displays the minimum temperature measured at this sensor.
This field displays the upper temperature limit at this sensor.
This field displays
for temperatures below the threshold and
No rm a l
A properly functioning fan is an essential component (along with a sufficiently ventilated, cool
operating environment) in order for the device to stay within the temperature threshold. Each fan
has a sensor that is capable of detecting and reporting if the fan speed falls below the threshold
shown.
This field displays this fan's current speed in Revolutions Per Minute (RPM).
This field displays this fan's maximum speed measured in Revolutions Per Minute (RPM).
This field displays this fan's minimum speed measured in Revolutions Per Minute (RPM). "<41" is
displayed for speeds too small to measure (under 2000 RPM).
This field displays the minimum speed at which a normal fan should work.
indicates that this fan is functioning above the minimum speed.
No rm a l
fan is functioning below the minimum speed.
The power supply for each voltage has a sensor that is capable of detecting and reporting if the
voltage falls out of the tolerance range.
This is the current voltage reading.
This field displays the maximum voltage measured at this point.
This field displays the minimum voltage measured at this point.
This field displays the percentage tolerance of the voltage with which the Switch still works.
indicates that the voltage is within an acceptable operating range at this point;
No rm a l
otherwise
is displayed.
Erro r
in the navigation panel to display the screen as shown.
GS1920v2 Series User's Guide
79
for those above.
Erro r
indicates that this
Erro r
>
Ba sic Se tting

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents