Table 145 Advanced Application > OAM Status > OAM Details (continued)
L ABEL
DESC RIPT IO N
Discovery state This field indicates the state in the OAM discovery process. OAM-enabled devices use this
process to detect each other and to exchange information about their OAM configuration
and capabilities. OAM discovery is a handshake protocol.
: One of the devices is transmitting OAM PDUs with link fault information, or the interface is
Fa ult
not operational.
Ac tive Se nd L o c a l
OAM.
Pa ssive Wa it
discovery.
Se nd L o c a l Re m o te
The port has discovered the remote device but has not accepted or rejected the
connection yet.
The port has discovered the remote device and rejected the connection.
Se nd L o c a l Re m o te O K
connection. In addition, the remote device has not accepted or rejected the connection
yet, or the remote device has rejected the connected.
Se nd Any
operating state for OAM links that are fully operational.
Remote Client
MAC address
This field displays the MAC address of the IEEE 802.3ah-enabled remote Ethernet device that is
connected to the Switch.
Vendor(oui)
This field displays the Organizationally Unique Identifiers (OUI) representing the vendor of the
IEEE 802.3ah-enabled remote Ethernet device that is connected to the Switch.
Statistics
This section displays the number of OAM packets transferred on the port of the Switch.
Information
This field displays the number of OAM PDUs sent on the port.
OAMPDU Tx
Information
This field displays the number of OAM PDUs received on the port.
OAMPDU Rx
Event Notification
This field displays the number of unique or duplicate OAM event notification PDUs sent on the
OAMPDU Tx
port.
Event Notification
This field displays the number of unique or duplicate OAM event notification PDUs received on
OAMPDU Rx
the port.
Loopback Control
This field displays the number of loopback control OAM PDUs sent on the port.
OAMPDU Tx
Loopback Control
This field displays the number of loopback control OAM PDUs received on the port.
OAMPDU Rx
Variable Request
This field displays the number of OAM PDUs sent to request MIB objects on the remote device.
OAMPDU Tx
Variable Request
This field displays the number of OAM PDUs received requesting MIB objects on the Switch.
OAMPDU Rx
Variable Response
This field displays the number of OAM PDUs sent by the Switch in response to requests.
OAMPDU Tx
Variable Response
This field displays the number of OAM PDUs sent by the remote device in response to requests.
OAMPDU Rx
Chapter 34 OAM
: The port is in active mode and is trying to see if the remote device supports
: The port is in passive mode and is waiting for the remote device to begin OAM
: This state occurs in the following circumstances.
: The port has discovered the remote device and has accepted the
: The port and the remote device have accepted the connection. This is the
GS1920v2 Series User's Guide
312

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents