Table 11 Basic Setting > System Info > Hardware Monitor (Stacking Mode) (continued)
LABEL
Voltage (V)
Current
MAX
MIN
Threshold
Status
Power Source
Status

6.2 General Setup

Use this screen to configure general settings such as the system name and time. Click Basic
Setting > General Setup in the navigation panel to display the screen as shown.
Figure 27 Basic Setting > General Setup
The following table describes the labels in this screen.
Table 12 Basic Setting > General Setup
LABEL
System Name
Location
Chapter 6 Basic Setting
DESCRIPTION
The power supply for each voltage has a sensor that is capable of detecting and reporting if
the voltage falls out of the tolerance range.
This is the current voltage reading.
This field displays the maximum voltage measured at this point.
This field displays the minimum voltage measured at this point.
This field displays the percentage tolerance of the voltage with which the Switch still works.
Normal indicates that the voltage is within an acceptable operating range at this point;
otherwise Error is displayed.
The power source of the Switch has a sensor that is capable of detecting and reporting if
the power source falls out of the normal status.
Normal indicates that the power source is within normal status. Error indicates that the
power source is not within normal status. Absent indicates that you do not insert the
power module. Present indicates that you insert the power module, but there is no
available power.
DESCRIPTION
Type a descriptive name for identification purposes. This name consists of up to 64
printable ASCII characters; spaces are allowed.
Type the geographic location of your Switch. You can use up to 32 printable ASCII
characters; spaces are allowed.
GS3700/XGS3700 Series User's Guide