Taiko™ Banknote Validator
ENABLING TAIKO FEATURES
™
The Taiko
setting for Banknote Acceptance and Front Panel LED Color
Pattern oscillations can be changed using DIP Switch enable routines.
D
ENOMINATION
Specific Banknote denominations can either be accepted or rejected. To enable
the acceptance of particular Banknote denominations, use the following
"
Accept Mode
Accept Mode
To enable Banknote acceptance, proceed as follows:
1. Remove power from the Taiko
2. Set DIP Switches #1 and #6 to ON.
3. Reapply power to the Unit.
4. After the Front Panel LED flashes WHITE, turn DIP Switch #1 OFF.
The
BLUE
5. Insert the Banknote to be accepted.
The Banknote will be read and held in place, and the
(Steady). The Banknote will then be returned, and the
Acceptance of the selected Banknote denomination is now enabled.
6. Continue to insert each desired Banknote denomination that is to be accepted.
7. When done, remove power from the Taiko
their normal operating positions, and reapply power to the Unit.
To disable the acceptance of particular Banknote denominations, use the
following "
Inhibit Mode
Banknotes programmed in the existing operating software.
Inhibit Mode
To allow the Taiko
ination, proceed as follows:
1. Remove power from the Taiko
2. Set DIP Switches #1, #6 and #7 to ON.
3. Reapply power to the Unit.
4. When the WHITE LED flashes, turn DIP Switch #1 OFF.
5. When the
is to be disabled or not to accepted.
The
ORANGE
returned. This denomination of Banknote is now inhibited from being accepted.
6. Continue inserting each specific denomination Banknote to be inhibited.
7. When done, remove power from the Taiko
their normal operating positions, and reapply power to the Unit.
Part No. 960-100919R_Rev. 1
JCM Training Overview
S
ETTINGS
" Procedure.
LED will begin to flash.
" Procedure. The default setting is to accept all
™
Unit to reject or not accept a particular Banknote denom-
BLUE
LED flashes, then flashes ORANGE, insert the Banknote that
LED will light steady while the Banknote is accepted and
™
Unit.
™
Unit, reset the DIP Switches to
™
Unit.
™
Unit, reset the DIP Switches to
5
March, 2017
BLUE
LED will be ON
BLUE
LED will flash.
© 2017 JCM American Corporation