Select An Operating Location; Cooling And Power Requirements - Compaq StorageWorks SAN Director 64 Installation Manual

Table of Contents

Advertisement

Standard flat-tip and cross-tip Phillips screwdrivers—Required to remove, replace,
adjust or tighten various FRUs, chassis, or cabinet components.
Electrostatic discharge (ESD) grounding cable with attached wrist strap—Required
when working in and around the Director card cage.
Maintenance terminal (desktop or notebook computer)— Required to configure
Director network addresses and acquire event log information through the
maintenance port. Computer requirements include:
Microsoft Windows 98, Windows NT 4.0, Windows 2000, or Windows
Millennium Edition operating system installed
RS-232 serial communication software (for example, ProComm Plus or
HyperTerminal).

Select an Operating Location

Install the Director in a secure or limited-access area to ensure that cable connections are
not compromised. Also, make sure to install the Director in an area with the ventilation
and power requirements described next.

Cooling and Power Requirements

Two fan modules, each containing three fans (six fans total), provide cooling for the
Director, as well as redundancy if a fan fails. The air intake for the director must satisfy an
operating environment temperature requirement of 40
Director power requirements are listed next.
Input voltage: 100 to 120 or 200 to 240 VAC
Input frequency: 50/60 Hz
CAUTION: Do not block SAN Director 64 air vents. The switch uses ambient air for
cooling.
Installing and Configuring the SAN Director 64
F to 104
°
°F
2–3
(4
C to 40
C).
°
°