3–4
SAN Director 64 Installation Guide
b. Click the checkbox in the Blocked column to block or unblock a port (default is
unblocked). A check mark indicates a blocked port. Blocking a port prevents the
attached device from communicating with the Director.
Figure 3–3: Configure ports
c. Click the checkbox in the 10-100 km column to enable extended distance buffering
for a port (the default is disabled). A check mark in the box enables extended
distance operation up to 100 kilometers (through repeaters).
2. Scroll down to the bottom of the page and click the Activate button to save the
information. The message "Your changes to the port configuration have been
successfully activated" appears.

Configure Director Identification

Perform this procedure to configure the Director name, description, location, and contact
person. The Name, Location, and Contact variables configured here correspond
respectively to the SNMP variables sysName, sysLocation, and sysContact. SNMP
management workstations use these variables to obtain data from Directors.
Use the following steps to configure the Director identification.
1. At the Configure panel, click the Director tab. The Director page displays with
Identification selected as shown in
Figure
3–4.