3–8
SAN Director 64 Installation Guide
4. Click the Director tab, then select the Operating Parameters option. The Director page
displays with Operating Parameters selected. See
Figure 3–7: Configure Director, Operating Parameters
a. At the BB_Credit field, type a value between 1 and 60 buffers. The default value is
16. Use a value of 60 buffers only for extended distance port operation.
b. At the R_A_TOV field, type a value between 10 through 1200 tenths of a second
(one through 120 seconds). The default value is 100.
c. At the E_D_TOV field, type a value between 2 through 600 tenths of a second (0.2
through 60 seconds). The default value is 20.
NOTE: All fabric-attached Directors and switches must be set to the same
E_D_TOV
Director segments and the Director cannot communicate with the fabric. In addition, the
R_A_TOV must be greater than the E_D_TOV. Compaq recommends that you obtain assistance
from the Professional Services Organization prior to changing the default values.
d. At the Preferred Domain ID field, type a value between 1 through 31 (default is 1).
The domain ID uniquely identifies each Director or switch in a fabric.
NOTE: All fabric-attached Directors and switches must have unique domain IDs. If the value is
not unique, the E_Port connection to the Director will segment and the Director will not be able
to communicate with the fabric.
operating values. If the values are incompatible, the E_Port connection to the
Figure
3–7.
R_A_TOV and