CHAPTER 5 Splashproof-II TPU
5.6.1
Linux TPU Updater is started by double-clicking the Linux TPU Updater icon
on the Windows desktop. The Klein Linux TPU Updater dialog box will open as
shown Figure 5-7.
5.6.2
The SP-II TPU IP address is set up at the factory. However, should a different
address be required, it can be changed.
To change the SP-II TPU IP address:
Connect the supplied configuration cable to the NAV connector of the
1.
SP-II TPU and to an available serial port on the laptop computer using the
supplied USB/RS-232 converter.
2. Turn on the laptop computer and wait for the Windows desktop to appear.
3. Turn on the SP-II TPU by switching the A/C-D/C switch to A/C for AC operation
or to D/C for DC operation.
4. Start Linux TPU Updater.
The Klein Linux TPU Updater dialog box opens.
5. Click Read TPU IP Address .
The Select RS-232 Port dialog box shown in Figure 5-8 opens.
6. From the Port drop-down list box, select the serial port on the laptop computer to
which the SP-II TPU is connected.
Series 3000 Sonar System Operations and Maintenance Manual

Starting Linux TPU Updater

The Klein Linux TPU Updater Dialog Box
Figure 5-7:

Querying or Changing the SP-II TPU IP Address