$Cmpcal=d:
$Cgo:
$MA0:
$MB0:
Turn the towfish off and then on again and check that the compass is working.
C.6.17 Calibrating the Compass with a
Magnetometer (Optional)
Before running the compass calibration, you must turn off the magnetometer
uplink.
To calibrate the compass with a magnetometer:
1. Open the startup.ini file in the klein directory.
2. Change the line set DEFAULTUPLINK 1 to set DEFAULTUPLINK 0.
3. Save the startup.ini file.
4. Run the compass calibration as described in "Calibrating the Compass" on page
C-38.
5. Open the startup.ini file and change set DEFAULTUPLINK 0 back to
DEFAULTUPLINK 1.
C.6.18 Series 3000 Sonar System Towfish Commands
The following are multiplexer commands:
$MLn:
$MHn:
The following are transmitter commands:
$MAF:
$MA0:
$MBF:
$MBO:
Disables compass multi-point calibration mode.
Starts compass.
Turn on low frequency transmitter.
Turn on high frequency transmitter.
Low frequency TVG page select. 7 is default.
High frequency TVG page select. 7 is default.
Turns the 100-kHz transmitter off.
Turns the 100-kHz transmitter on.
Turns the 500-kHz transmitter off.
Turns the 500-kHz transmitter on.